1. Home >
  2. Support >
  3. Record of V-SFT-6 version updates

Record of V-SFT-6 version updates

 
June 2017 Ver. 6.0.24.0
V9 series SYS PROG:version V1.470, OS:version V2.90
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.230
TS1000 series SYS PROG:version V2.230
V-SFT-6: Failure fixed.
 
May 2017 Ver. 6.0.23.0
V9 series SYS PROG:version V1.470, OS:version V2.90
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.230
TS1000 series SYS PROG:version V2.230

V9/TS/V8 series: PLCs newly supported.
- Yaskawa Electric DX200(High Speed Ethernet) supported.
- High-Pressure Gas Industry R-BLT supported.

April 2017 Ver. 6.0.22.0
V9 series SYS PROG:version V1.430, OS:version V2.90
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.220
TS1000 series SYS PROG:version V2.220

V9/TS/V8 series: PLCs newly supported.
- WAGO %MW address range extended.
- PROFIBUS-DP Individual settings of the Input/Output Byte Counts Setting supported.
- Siemens S7 PROFIBUS-DP Individual settings of the Input/Output Byte Counts Setting supported.
- Hitachi HIDIC-S10(OPCN-1) supported.
- MITSUBISHI ELECTRIC MR-J4-*A supported.
- Fuji Electric MICREX-SX series SPF supported.

V9 series: Remote Desktop function supported.
V9 series: Area transparent of Trend display area supported.
V9 series: PDF Viewer function enhanced.
V9 series: Multi-line title in the CSV Format Setting of Alarm Server/Logging Server supported.
V9 series: Individual device designation in the Transfer Device Setting of the Recipe Data supported.
V9 series: Display items such as V8 Compatible in General Setting added.
V9 series: SANEI ELECTRIC printer supported.
V9 series: Specifications of Macro command SYS(RESTART) changed.
V9 series: Multi-line display in Flowing Message Settings supported.
V9 series: Default settings for Use the monitoring function in VPN Setting changed.
V9 series: Specifications of the Communication Setting changed.
TS series: VNC server function added.
V-SFT-6: Switch - Transparent switch function added.
V-SFT-6: Q/I/M devices in importing Tags for Siemens TIA supported.
V-SFT-6: Specifications of the string registration method in String table changed.
V-SFT-6: Specifications of the Control Device in Overlap during V9 conversion changed.
V-SFT-6: Specifications of the ON Grid in the Grid Setting changed.
Dec 2016 Ver. 6.0.21.0
V9 series SYS PROG:version V1.360, OS:version V2.80
V8 series SYS PROG:version V2.190
TS2000 series SYS PROG:version V2.200
TS1000 series SYS PROG:version V2.190

V9/V8 series: PLCs newly supported.
- JTEKT:TOYOPUC-Nano(Ethernet) supported.
- FESTO:FEC Series supported.
- SAIA:PCD DataMode supported.

V9 series: TELLUS and V-Server supported.
V-SFT-6: TELLUS Ver.4 supported.
Oct 2016 Ver. 6.0.20.0 a
V9 series SYS PROG:version V1.310, OS:version V2.70
V8 series SYS PROG:version V2.190
TS2000 series SYS PROG:version V2.190
TS1000 series SYS PROG:version V2.190
V-SFT-6: Failure fixed.
Oct 2016 Ver. 6.0.20.0
V9 series SYS PROG:version V1.310, OS:version V2.70
V8 series SYS PROG:version V2.190
TS2000 series SYS PROG:version V2.190
TS1000 series SYS PROG:version V2.190
V9 series: System Program and OS fixed.
Oct 2016 Ver. 6.0.19.0
V9 series SYS PROG:version V1.300, OS:version V2.60
V8 series SYS PROG:version V2.190
TS2000 series SYS PROG:version V2.190
TS1000 series SYS PROG:version V2.190

V9/V8 series: PLCs newly supported.
- OMRON NJ Series(EtherNet/IP) supported.
- Yaskawa Electric MP3000 Series supported.
- DELTA DVP-SE(MODBUS ASCII) supported.
- DELTA DVP-SE(MODBUS TCP/IP) supported.

VPN additional functions (retry, connection condition $s1679)
July 2016 Ver. 6.0.18.0
V9 series SYS PROG:version V1.270, OS:version V2.60
V8 series SYS PROG:version V2.170
TS2000 series SYS PROG:version V2.180
TS1000 series SYS PROG:version V2.170
V9 series: System Program fixed.
V9 series: System language display in accordance with multi-language setting supported.
July 2016 Ver. 6.0.17.0
V9 series SYS PROG:version V1.250, OS:version V2.60
V8 series SYS PROG:version V2.170
TS2000 series SYS PROG:version V2.170
TS1000 series SYS PROG:version V2.170

V9/V8 series: PLCs newly supported.
- RKC REX-F9000(Standard Protocol)supported.
- Modbus slave(RTU) RS422 (4-wire) supported.
- Modbus slave(ASCII) RS422 (4-wire) supported.
- RS Automation X8 Series: Offset designation of ST device changed.
- RS Automation X8 Series(Ethernet) Offset designation of ST device changed.

V9 series: Web Machine Interface Cloud Data Service Ver. 1.0 supported.(Operation to be started in August 2016)
V9 series: Web Machine Interface VPN unencryption communication setting supported.
V9 series: GUR-01(RGB IN-1CH) remake supported.
V9 series: Network printer supported.
V9 series: Scroll function added.
V-SFT-6: Associating a [*.V8] file with V-SFT-6 during installation supported.
June 2016 Ver. 6.0.16.0
V9 series SYS PROG:version V1.230, OS:version V2.50
TS2000 series SYS PROG:version V2.160

V9/V8 series: PLCs newly supported.
- KEYENCE KZ/KV series CPU supported.
- Siemens S120 (Ethernet ISOTCP) supported.

V9 series: Gothic font (V8 compatible) supported .
TS series: TS2000 series supported.
V-SFT-6: Selection environment - hiding other items than target select items supported.
April 2016 Ver. 6.0.15.0
V9 series SYS PROG:version V1.210, OS:version V2.40
V8 series SYS PROG:version V2.150

V9 series: PLCs newly supported.
- Siemens S7-300/400MPI Ladder Transfer Function supported.

V9/V8 series: PLCs newly supported.
- Yaskawa Electric MP3000 Series (Ethernet UDP/IP) supported.
- A&D AD4402(MODBUS RTU) supported.
- A&D AD4404(MODBUS RTU) supported.
- FUJI FRENIC-Mini (MODBUS RTU)(C2) supported.
- FUJI FRENIC Series (CPU) supported.
- FUJI FRENIC Series (CPU) Ladder Transfer Function supported.
- FATEK AUTOMATION FACON FB Series Ladder Transfer Function supported.
- KEYENCE KZ24/300 CPU supported.

V9 series: Video / RGB unit "GUR-00", "GUR-10", and "GUR-11" supported.
V9 series: Screen program transfer - TCP/IP communication supported.
V9 series: DHCP server (WLAN port) supported.
V9 series: Data transfer viewer supported.
V9 series: Data transfer service - device designation of folder name / file name supported. Filter function supported.
V9 series: Substitute function for Memory card mode (V8 compatible) supported.
V9 series: Video / RGB-IN enlarge display (V8 compatible) supported.
V9 series: Logging server and Alarm server - compatible $s regsiteres with buffering area supported.
V9 series: SRAM capacity for Operation log function extended.
V-SFT-6: Symbol import for Siemens TIA Portal supported.
V-SFT-6: Microsoft Windows 10 supported.
V-SFT-6: HEX designation for bit device of MITSUBISHI PLC device supported.
V8 series: "GU-01","GU-10", and "GU-11" revised hardware supported.
January 2016 Ver. 6.0.14.0
V9 series SYS PROG:version V1.180, OS:version V2.30
V8 series SYS PROG:version V2.130
V9/V8 series: PLCs newly supported.
- Yaskawa Electric MP3000 Series EXPANSION MEMOBUS(Ethernet) supported.
- Lenze ServoDrive9400(Ethernet TCP/IP) supported.
- Siemens S7-200 PPI Ladder Transfer Function supported.
V9 series: GD-80E/V609E compatibility supported.
V9 series: DHCP client function supported.
V-SFT-6: Speed up launching when opening a screen program supported.
November 2015 Ver. 6.0.13.0
V9 series SYS PROG:version V1.160, OS:version V2.20
V8 series SYS PROG:version V2.130
V9/V8 series: PLCs newly supported.
- FUJI FRENIC-Ace (MODBUS RTU) supported.
- YOKOGAWA UT32A/35A(MODBUS RTU) supported.
- YOKOGAWA UT52A/55A(MODBUS RTU) supported.
- YOKOGAWA UT75A(MODBUS RTU) supported.
V9 series: Path through function supported with external devices connected via LAN port.
V9 series: XOR drawing mode (V8 compatible) supported with numeric data display, switches, and lamps.
October 2015 Ver. 6.0.12.0
V9 series SYS PROG:version V1.140, OS:version V2.10
V8 series SYS PROG:version V2.130
V9/V8 series: PLCs newly supported.
- MITSUBISHI FX5U/5UC series supported.
- MITSUBISHI FX5U/5UC series (Ethernet) supported.
- MITSUBISHI FX3U/3GE series(Ethernet)supported.
- MITSUBISHI L series CPU supported.
- KEYENCE KV-7000 (Ethernet TCP/IP) supported.
- FUJI PXF(MODBUS RTU) supported.
- Azbil SDC15 supported.
- Azbil SDC25/26 supported.
- Azbil SDC45/46 supported.
V8 series: PLCs newly supported.
- YOKOGAWA μR10000/20000 (Ethernet TCP/IP) supported.
V9 series: Animation Viewer supported.
V9 series: PDF Viewer function addition
Ladder Transfer Function:Flow Control supported (When MITSUBISHI A series CPU is selected)
V-SFT-6: Display device address with zero suppress
July 2015 Ver. 6.0.11.0
V9 series SYS PROG:version V1.120, OS:version V2.00
V8 series SYS PROG:version V2.090
V9 series: PLCs newly supported.
- YOKOGAWA μR10000/20000(Ethernet TCP/IP) supported.
V9/V8 series: PLCs newly supported.
- FUJI FRENIC-VG1(MODBUS RTU) supported.
- FUJI HFR-K1K supported.
- Azbil SDC45/46 supported.
- OMRON V680S(Ethernet TCP/IP) supported.
V9 series: V9HDCOPY macro supports data save in JPEG format.
V9 series: Data sheet printing: Saving a PDF file without time stamp supported.
V9 series: Alarm parts (V8 compatible) supports scroll bar function.
V9 series: Security function supports login/logout macro commands.
May 2015 Ver. 6.0.10.0
V9 series SYS PROG:version V1.110, OS:version V1.90
V8 series SYS PROG:version V2.090
V9 series: System Program and OS fixed.
Apr 2015 Ver. 6.0.9.0
V9 series SYS PROG:version V1.100, OS:version V1.80
V8 series SYS PROG:version V2.090
V9 series: PLCs newly supported.
- Communication units supported (CC-Link/PROFIBUS/DeviceNet) .
V9/V8 series: PLCs newly supported.
- Siemens S7-1200/1500(Ethernet ISOTCP) connection supported.
- RS Automation CSD5(MODBUS RTU) connection supported.
- RS Automation Moscon-F50(MODBUS RTU) connection supported.
- MITSUBISHI iQ-R series(Built-in Ethernet) connection supported.
- MITSUBISHI iQ-R seriles link connection supported.
- MITSUBISHI iQ-R series(Ethernet) connection supported.
V9 series: Ladder monitor supported (FUJI)
V9 series: Ethernet network table edit from the local screen supported.
V9 series: Selectable font size supported with alarm display (V8 compatible), bit sampling (V8 compatible), and data sampling function.
Mar 2015 Ver. 6.0.8.0
V9 series SYS PROG:version V1.090, OS:version V1.70
V8 series SYS PROG:version V2.090
V9 series: PLCs newly supported.
- Universal serial : Word count of write command increased.
V-SFT-6: LogToCSV (CSV conversion tool for operation log data) : V9 data (*db) supported
Feb 2015 Ver. 6.0.7.0
V9 series SYS PROG:version V1.080, OS:version V1.60
V8 series SYS PROG:version V2.090
V9 series: System Program fixed.
V-SFT-6: Failure fixed.
Feb 2015 Ver. 6.0.6.0
V9 series SYS PROG:version V1.070, OS:version V1.50
V8 series SYS PROG:version V2.080

V9 series: PLCs newly supported.
-Communication units supported (Ethernet/OPCN-1/Fl-Net) .
V9/V8 series: PLCs newly supported.
-FUJI ALPHA5 (MODBUS RTU) parameter range extended.
V8 series: PLCs newly supported.
-DELTA DVP series Multi-link2 Ethernet connections supported.

V9 series: Video (1ch), RGB-IN (1ch), and RGB-OUT (1ch) supported.
Jan 2015 Ver. 6.0.5.0
V9 series SYS PROG:version V1.060, OS:version V1.40
V8 series SYS PROG:version V2.080

V9/V8 series: PLCs newly supported.
-Modbus slave(ASCII) connection supported.
-TOSHIBA VF-S15 connection supported.
-TOSHIBA VF-MB1 connection supported.
-TOSHIBA VF-nC3 connection supported.
-Allen-Bradley Micro800 Controllers connection supported.
-Allen-Bradley Micro800 Controllers(Ethernet TCP/IP) connection supported.
-Allen-Bradley Micro800 Controllers(Ethernet TCP/IP) connection supported.

V9 series: Printer type added.
-PR201 Monochrome / Color supported.
-ESC/P Monochrome / Color supported.
-CBM292/293 supported.
-MR400 supported.

V9 series:Trend: Background function supported.
V9 series:Text table supported.
V9 sereis:PDF viewer supported.
V9 series:Entry: Direct function supported.
V9 series:FTP client function supported.
V9 series:Ladder monitor function supported. (MITSUBISHI/OMRON/YOKOGAWA)
V-SFT-6: V9150/V9120/V907xW/V9060 added to edit model.
V-SFT-6: V8 added to edit model.
V-SFT-6: Comment edit function supported with Message edit.
Oct 2014 Ver. 6.0.4.0
SYS PROG:version V1.050, OS:version V1.30

PLCs newly supported.
- Multi-link connection supported.
- Multi-link2 Ethernet and 1:n Multi-link2 Ethernet connections supported.
- PLC ladder transfer function 3Way supported.

Overlap - Specifying superimpose color supported.
Switch - Switching to Local Mode function supported.
Alarm Tracking (V8 compatible) - Time lag display supported.
Animation function supported.
Storage setting - Pattern, 3D parts, and Windows font supported.
Line width specified by point supported.
Operation log - Saving settings of sort, filter, search, and display settings supported.
Recipe - semicolon (;) as CSV file separator supported.
VNC server - System memory supported.
VNC authentication screen - User-defined splash screen supported.
General Settings - Hide Check Screen supported.(Check Screen = Data Loading)
Rotate display of the Check screen supported.(Check Screen = Data Loading)
V-SFT-6: Widows8.1 supported.
V-SFT-6: File conversion from V7/V6/V4/GD80 to V9 supported.
V-SFT-6: Pasting MS Office drawings on the software supported.
V-SFT-6: DXF file conversion feature enhanced.
V-SFT-6: GD-80E/V609E compatible setting - color batch change supported.
Part frame fix supported with the parts other than switch/lamp.
Macro GET_SMPL , SAMPLE supported with V9.
CF Card Function(VCFAcs.DLL)supported.
Sep 2014 Ver. 6.0.3.0
SYS PROG: version V1.040, OS: version V1.20

PLCs newly supported.
- Monitor command supported.
[Supported model]
Panasonic: FP Series(RS232C/422),FP Series(Ethernet TCP/IP),
FP Series(Ethernet UDP/IP),FP-X(Ethernet TCP/IP)
SAMSUNG: SECNET
RS OEMax: N7/NX Series(70/700/750/CCU)  
- Multi-link2 (serial) supported.

VPN function improved.
Macro command compatible with V8 (SYS(GET_SMPL)) supported.
Jul 2014 Ver. 6.0.2.0
SYS PROG: version V1.030, OS: version V1.10

PLCs newly supported.
- FUJI:MICREX-F Tlink / MICREX-F Tlink V4 Compatible supported.
- FUJI:MICREX-SX(Tlink) supported.
- FUJI:MICREX-SX(SX bus) supported.
- Modbus Slave(TCP/IP) supported.
- Ladder transfer function added.

VPN function supported.
Overlay display of trend graph supported.
Storing messages into a storage supported.
OS automatic upload function supported.
Emulator supported.
Recipe dialog function supported.
V-SFT-6: High speed data transfer supported.
V-SFT-6: MICREX-SX variable names cooperation supported.
V-SFT-6: Chinese (simplified, traditional) and Korean supported (available with other languages than Japanese).
V-SFT-6: Fixing 3D parts frame supported.
V-SFT-6: Plate parts supported.
V-SFT-6: Switch - accumulation function supported.