How to display overlap parts from the PLC (external)
There are four overlap part types.
- Normal overlap
- Call-overlap
- Multi overlap
- Global overlap
In the case of external commands, the display method differs.
[Normal/call overlap]
Two methods are available.
<Using the read area>
The overlap part will be displayed when bit 0 to 2 of read area "n + 1" corresponding to the desired overlap ID number is turned ON.
* For details about how to check Read area, click here.
<Using the control device memory>
Check [Control Device] in the [Overlap] dialog on the V-SFT-6 editor.
The overlap part will be displayed when bit 0 of the specified cotrol device memory is turned ON.
Example: Normal overlap
[Multi/Global overlap]
Two methods are available.
<Using the read area>
- Display the [Overlap] dialog or select [System Setting] → [Global Setting] → [Global Overlap Setting], and select [Display Method: Control Device] on the V-SFT-6 editor.
Set the PLC device memory for [Info Output Device].
A device memory address is set for [Device Overlap Library No. to Display] (= information output device "n + 1").
(The overlap library number to be displayed is stored in this device memory address.)
Example: Multi-overlap
Contents of info output device
* Valid when the [Specify the display position by device] is checked.Device Contents Operation n The overlap library number of the multi/global overlap part currently displayed on the screen is stored.
When no overlap display is shown, "-1" is stored.V/TS→PLC n+1 Specify the overlap library number to be displayed. V/TS←PLC n+2 * Specify the X coordinate of the multi/global overlap display. V/TS←PLC n+3 * Specify the Y coordinate of the multi/global overlap display. V/TS←PLC
- The overlap part will be displayed when the bit of read area "n + 1" corresponding to the desired overlap ID number is turned ON.
- Multi overlap: Bit 0 to 2 of read area "n + 1"
- Global overlap: Bit 3 of read area "n + 1"
* For details about how to check Read area, click here.
<Using the control device memory>
- Display the [Overlap] dialog or select [System Setting] → [Global Setting] → [Global Overlap Setting], and select [Display Method: Control Device] on the V-SFT-6 editor.
Set the PLC device memory for [Info Output Device]. - Check [Control Device].
- A device memory address is set for [Device Overlap Library No. to Display] (= information output device "n + 1").
(The overlap library number to be displayed is stored in this device memory address.)
Example: Multi-overlap
* For more information of the Info Output Device, refer to the "Contents of info output device" above. - The overlap part will be displayed when the number to display is set for [Device Overlap Library No. to Display] set in step (1) and bit 0 of the control device memory is turned ON.