Fuji Electric Co.,LTD
Global
Hakko Electronics (Europe)
Select Region
  • Global
  • Europe
  • Japan
  • China
  • Asia
    • Taiwan
    • Korea
Print
Font Size
  • Small
  • Medium
  • Large
  • Home
  • HMI
  • Company profile
  • » Products
  • » Support
  • » FAQ
  • » Distributors
  1. Home >
  2. FAQ
V10/V9 series Error HKFAQ000302

date: 2024/8/26

When the MICREX-SX PLC is connected via the SX bus, the V10/V9 series unit encounters a communication error ("Time-Out") at startup.

Check the [Waiting time for structure check] and [Fail-soft operation setting] settings on the SX side.

  • If the [Waiting time for structure check] setting is too short, an error (serious fault) may occur in the configuration check because the V10/V9 series unit will not start up in time.
  • Configuring a fail-soft startup setting will prevent a serious fault from occurring even if the V10/V9 series unit does not start up in time for the configuration check and thereby prevent a communication error.

 

 

 

The setting procedure is described using the "SX-Programmer Expert (D300Win)" SX tool software as an example. The setting procedure is the same for "SX-Programmer Standard".

 

Waiting time for configuration check

  1. Click [System properties] in the system definition window and then click the [Properties] button.
  2. Set [Waiting time for structure check] on the [System Running Definition] tab window as follows.

    V10: 20 (s)
    V9: 30 (s)

Fail-soft operation setting

  1. Click the [Fail-soft operation setting] tab in the [System properties] window.
  2. Select [Partial Fail-soft start up] and a value for [Start Station No. of fail-soft running] in the [Fail-soft start up mode selection] area.

      * Set a value so that the SX station number of the V10/V9 series unit is included in the fail-soft startup.

        
  

* For more information on the configuration check wait time and fail-soft startup operation mode, refer to the SX manual.
* For information on how to use "SX-Programmer Expert (D300Win)" and "SX-Programmer Standard", refer to the corresponding manual.

Was this page helpful?

Please cooperate with the questionnaire to make it better.

Related questions(FAQ)

  • Communication Error "Timeout"
  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • » Inquiries about products
  • » Inquiries about sales
  • » Request for catalogs
  • » Compliance with the RoHS

MONITOUCH

LINE UP
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
Support »
  • Download
  • Inquiries
  • Recommended peripheral equipment
FAQ »
  • FAQ concerning MONITOUCH
Distributors »
  • Overseas distributors
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved