V10/V9 series Questions about HKFAQ000079

date: 2017/9/20

How to read or write data between the temperature controller/inverter and the PLC device memory or internal device memory at regular intervals

Use the [Device Memory Map] setting.
Setting location: [System Setting] -> [Device Memory Map]

[Reading temperature controller/inverter data at regular intervals] (periodic reading)

  1. Click [System Setting] -> [Device Memory Map] -> [PLCn].
    The [Transfer Table: PLCn] menu is displayed.

    How to read or write data between the temperature controller/inverter and the PLC device memory or internal device memory at regular intervals

  2. Click [Edit] -> [Device Memory Map Setting] to display the [Device Memory Map Setting [n]] window.
    Set [Function] as [Periodical Reading] and then configure [Reading Cycle] and [Target Device] (PLC or internal device memory).


    Example: Transferring temperature controller/inverter data to the PLC or internal device memory every 10 seconds
    How to read or write data between the temperature controller/inverter and the PLC device memory or internal device memory at regular intervals

  3. Double-click on each cell and configure settings.

 



[Writing temperature controller/inverter data at regular intervals] (periodic writing)

  1. Click [System Setting] -> [Device Memory Map] -> [PLCn].
    The [Transfer Table: PLCn] menu is displayed.

     

  2. Click [Edit] -> [Device Memory Map Setting] to display the [Device Memory Map Setting [n]] window.
    Set [Function] as [Periodical Writing] and then configure [Writing Cycle] and [Source Device] (PLC or internal device memory).

     Example: Transferring data in PLC device memory to a temperature controller/inverter every 10 seconds
     

  3. Double-click on each cell and configure settings.

    How to read or write data between the temperature controller/inverter and the PLC device memory or internal device memory at regular intervals

Was this page helpful?

Please cooperate with the questionnaire to make it better.

Related questions(FAQ)

  • How to check the communication condition between the temperature controller and the V series
  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • » Inquiries about products
  • » Inquiries about sales
  • » Request for catalogs
  • » Compliance with the RoHS

MONITOUCH

LINE UP
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
Support »
  • Download
  • Inquiries
  • Recommended peripheral equipment
FAQ »
  • FAQ concerning MONITOUCH
Distributors »
  • Overseas distributors
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved