At the start of communication, the V8/TS series initially displays the screen corresponding to the value specified for "n+2" in [Read Area].
 "Screen No. Error" is displayed when the screen number entered for "n+2" in [Read Area] does not exist in the screen program.
Check the value of "n+2" in [Read Area] and change it to the value of an existing screen number.
 If the device memory of [Read Area] is unknown, check the following locations.
V8/TS series
 Check position: V-SFT-6 editor [System Setting] → [Hardware Setting] → 
                         [Read/Write Area] → [Read Area]
Example) In the above screenshot, since the value of "n+2" in [Read Area] is "D00002", check the value of "D00002" on the PLC and change it to the value of an existing screen number if necessary.
* If the [GD-80 Compatible Read/Write Area] checkbox is selected in the
   [GD-80 Compatible] tab window, check the lower 8 bits of the device memory
   for "n+1" in [Read Area].
V7 series
 Check position: V-SFT-5 editor [System Setting] → [PLC Communication] → 
                         [Communication Parameter] → [Main 1]
 
Example) In the above screenshot, since the value of "n+2" in [Read Area] is "D00002", check the value of "D00002" on the PLC and change it to the value of an existing screen number if necessary.
* If the [GD-80 Compatible Read/Write Area] checkbox is selected, check the
   lower 8 bits of the device memory for "n+1" in [Read Area].
If "Screen No. Error" is displayed when the emulator starts
Double-click the value of "n+2" in [Read Area] displayed in the [System] window of the simulator and change it to the value of an existing screen number.
Was this page helpful?
Please cooperate with the questionnaire to make it better.