V8/TS2060 series Operation Troubles HKFAQ000127

date: 2021/7/6

Communication between the temperature controller and the V series is slow (V7 series).

To speed up communications, try the following method.
The condition can also be improved as described below.

 

<Baud rate>

Increase the communication speed (baud rate).
When changing the baud rate, be sure to change the settings on both the V series and the temperature controller.
Setting location: V-SFT editor [System Setting] → [Temperature Controller/PLC2Way Communication] → [Temperature Control/PLC2Way]

 

<When multiple temperature controllers are connected>

When multiple temperature controllers are connected, activate the communication with all temperature controllers.
This eliminates recovery confirmation accesses to stations where communication is down.

 

<Temperature control/PLC2Way table>

Use the [Temperature Control/PLC2Way Table] without placing temperature control memory directly on the screen.
Use [Temperature Control/PLC2Way Table] to transfer the temperature control memory to the internal memory and place the target internal memory on the screen.
If [Temperature Control/PLC2Way Table] is already used, separate the table for each station.
For more information about [Temperature Control/PLC2Way Table], refer to "How to read or write data between the temperature controller/inverter and the PLC memory or internal memory at regular intervals".

Was this page helpful?

Please cooperate with the questionnaire to make it better.

Related questions(FAQ)

  • How to read or write data between the PLC, temperature controller and inverter at regular intervals
  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • ≫ 產品諮詢
  • ≫ 營業銷售諮詢
  • ≫ 索取産品目錄
  • ≫ 支援RoHS指令

MONITOUCH

LINE UP
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
服務中心 ≫
  • 下載
  • 諮詢
  • 推薦外圍設備
FAQ(常見問題) ≫
  • FAQ concerning MONITOUCH
代理商 ≫
  • Overseas distributors
  • ≫ Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved