Fuji Electric Co.,LTD
Global
Hakko Electronics (Taiwan)
Select Region
  • Global
  • Europe
  • Japan
  • China
  • Asia
    • Taiwan
    • Korea
Print
Font Size
  • Small
  • Medium
  • Large
  • 首頁
  • HMI
  • 公司簡介
  • ≫ 產品情報
  • ≫ 服務中心
  • ≫ FAQ(常見問題)
  • ≫ 代理商
  1. 首頁 >
  2. 產品情報
V8/TS2060 series Operation Troubles HKFAQ000137

date: 2021/7/14

Previous numeric data or characters remain in a numerical data display or character display part.

 

<Causes>

TS/V8/V7 series
The number of parts with the [Transparent] or [Shadow] setting has exceeded the number available on one screen.

 

V6 series
Transparent disabled parts are configured with the [Transparent] or [Shadow] setting.

 

<Solutions>

Cancel the [Transparent] or [Shadow] setting and match the back color with background color. Change the part to the one having a box on the background. For precautions about the use of transparency, see below.

  • For TS series, click here.
  • For V8 series, click here.
  • For V7/V6 series, click here.

Was this page helpful?

Please cooperate with the questionnaire to make it better.

  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • ≫ 產品諮詢
  • ≫ 營業銷售諮詢
  • ≫ 索取産品目錄
  • ≫ 支援RoHS指令

MONITOUCH

LINE UP
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
服務中心 ≫
  • 下載
  • 諮詢
  • 推薦外圍設備
FAQ(常見問題) ≫
  • FAQ concerning MONITOUCH
代理商 ≫
  • Overseas distributors
  • ≫ Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved