V8/TS2060 series Questions about HKFAQ000171

date: 2021/8/3

How to set asynchronous display of multiple lines in a trend graph

Two or more trend graph parts in the same size must be overlaid.
It is possible to display the trend lines at different timings by linking the parts with each other.
 

Example: When drawing two lines in a trend graph at different timings:

 

  1. Place two trend graphs of the same size by overlaying one on another.
    Regard one trend graph as a "parent," and the other trend graph as a "child."

     

    V8series|How to set asynchronous display of multiple lines in a trend graph?

    The "parent" trend graph must be laid under the "child" trend graph.

     

  2. For the "child" trend graph, check [Overlap] and specify the same ID as the "parent" trend graph for [Link ID].

     

    V8series|How to set asynchronous display of multiple lines in a trend graph?

    When [Overlap] is checked in the "child" trend graph setting, "redraw" & "redraw after clear" commands at the "child" trend graph will be ignored and only commands from the control device memory of the "parent" trend graph will be acceptable.

     

    Control device memory for "parent" trend graph


    For more information about the control device memory, click here.

    For more information about setting procedure and display method, click here.

 

Was this page helpful?

Please cooperate with the questionnaire to make it better.

  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • ≫ 產品諮詢
  • ≫ 營業銷售諮詢
  • ≫ 索取産品目錄
  • ≫ 支援RoHS指令

MONITOUCH

LINE UP
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
服務中心 ≫
  • 下載
  • 諮詢
  • 推薦外圍設備
FAQ(常見問題) ≫
  • FAQ concerning MONITOUCH
代理商 ≫
  • Overseas distributors
  • ≫ Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved