V-SFT-6 Ver.6.2.7.0 → Ver.6.2.8.0 Date of Release 2025/10/1

◆Configuration Software
No Item Description TS/V8 V9 V10 X1
25A0H01 PLC model change Fixed the defect: When a Hitachi Industrial Equipment Systems HIDIC-H is changed to HIDIC-EHV (Ethernet), the device memory may not be converted correctly.
25A0H02 Conversion to rich text format Fixed the defect: When using [Tool] -> [Convert to Rich Text Format] on version 6.2.7.0, the editor is forcibly terminated upon selecting all and saving.
25A0H03 Macro command editing Fixed the defect: When the [Support Dialog] is displayed while the [Device Setting] window is displayed on the macro editing window and the data size is changed to “BIT” and overwritten, the [Device Setting] window stays displayed.
25A0H04 Windows fonts Fixed the defect: When the [Use Windows fonts] checkbox is selected for a string, the displayed font name is not the font that is specified from [Text Font].
25A0H05 Macro command editing Fixed the defect: Displaying the macro editing window after an error check may result in an error.
25A0H06 Macro command editing Fixed the defect: When the FATEK AUTOMATION FACON FBs Series (Ethernet) is selected as a PLC model, the PLC device memory port number that is set to other than “0” is changed to “0” when the macro editing window is closed and opened again.
25A0H07 SX variable name cooperation Fixed the defect: When a V8 screen program with SX variable name cooperation is converted to a V10 screen program without cooperation and the screen program is saved and opened again, the device memory of alarm blocks becomes invalid.
25A0H08 Improvement of vulnerability Improved vulnerabilities of V7 files
- Vulnerability of remote code execution caused by heap-based buffer overflow
- Vulnerability of remote code execution caused by stack-based buffer overflow

◆V10 series: System Program
No Item Description Altered
Ver.
OS
Ver.
25A0T01 RGB adjustment Fixed the defect: When using RGB input on a G type V10 series unit, the [I/O Check] -> RGB Adjustment screen in Local mode does not function correctly. 1.500
25A0T02 IP address setting Fixed the defect: Communication with a PLC cannot be established and a timeout communication error occurs under the following conditions.
- A screen program that has settings at [Local Port IP Address] -> [Set IP] that differ from the V10 series unit is transferred.
- IP settings are changed on the LAN Setting screen in Local mode.
1.500
25A0T03 Data sheet printing Fixed the defect: When printing data sheets, the print position of text and data displays may be displaced considerably. 1.500
25A0T04 Overlap display Fixed the defect: If an overlap display is continuously shown or hidden at short intervals, the actual display status of the overlap display and the registration/display status of the system device memory may become inconsistent. 1.500
25A0T05 Mouse cursor Fixed the defect: The mouse cursor may be displayed when a certain USB keyboard that supports “AC Pan”, which is equivalent to a horizontal scroll function, is connected. 1.60
25A0T06 Macro commands Fixed the defect: When the SYS (SAMPLE) macro command is executed, a memory leak occurs. 1.500
25A0T07 Lamps Fixed the defect: When a screen program has the [Bring lamp items to top if the status changes] setting enabled and lamps (rendering mode: REP) are placed overlapping each other, the ON display of a lamp in the background cannot be seen because it is hidden behind the front lamp. 1.500
25A0T08 Video, USB camera Fixed the defect: When an overlap display with a video or USB camera item is switched over continuously in a short period of time, the V10 series unit may reboot. 1.500

◆V10 series: Communication Driver
No Item Description Altered
Ver.
25A0U01 MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs.
- U003\G01002
- U004\G01002
1.710
25A0U02 MITSUBISHI ELECTRIC: FX5U/5UC series
MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet)
Fixed the defect: When communication exceeding the maximum I/O points of the PLC’s specification is attempted for multiple batch block write commands, a communication error occurs. 1.610
1.710

◆V9 series: System Program
No Item Description Altered
Ver.
OS
Ver.
25A0J01 Data sheet printing Fixed the defect: When printing data sheets, the print position of text and data displays may be displaced considerably. 3.300
25A0J02 Overlap display Fixed the defect: If an overlap display is continuously shown or hidden at short intervals, the actual display status of the overlap display and the registration/display status of the system device memory may become inconsistent. 3.300
25A0J03 Macro commands Fixed the defect: When the SYS (SAMPLE) macro command is executed, a memory leak occurs. 3.300
25A0J04 Lamps Fixed the defect: When a screen program has the [Bring lamp items to top if the status changes] setting enabled and lamps (rendering mode: REP) are placed overlapping each other, the ON display of a lamp in the background cannot be seen because it is hidden behind the front lamp. 3.300

◆V9 series: Communication Driver
No Item Description Altered
Ver.
25A0K01 MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs.
- U003\G01002
- U004\G01002
1.710
25A0K02 MITSUBISHI ELECTRIC: FX5U/5UC series
MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet)
Fixed the defect: When communication exceeding the maximum I/O points of the PLC’s specification is attempted for multiple batch block write commands, a communication error occurs. 1.610
1.710

◆TS/V8 series: System Program
No Item Description Altered
Ver.
25A0G01 MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs.
- U003\G01002
- U004\G01002
1.300
25A0G02 MITSUBISHI ELECTRIC: FX5U/5UC series
MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet)
Fixed the defect: When communication exceeding the maximum I/O points of the PLC’s specification is attempted for multiple batch block write commands, a communication error occurs. 1.200