V-SFT-6 Ver.6.2.7.0 → Ver.6.2.8.0 |
Date of Release |
2025/10/1 |
◆Configuration Software |
No |
Item |
Description |
TS/V8 |
V9 |
V10 |
X1 |
25A0H01 |
PLC model change |
Fixed the defect: When a Hitachi Industrial Equipment Systems HIDIC-H is changed to HIDIC-EHV (Ethernet), the device memory may not be converted correctly. |
● |
● |
● |
● |
25A0H02 |
Conversion to rich text format |
Fixed the defect: When using [Tool] -> [Convert to Rich Text Format] on version 6.2.7.0, the editor is forcibly terminated upon selecting all and saving. |
● |
● |
● |
● |
25A0H03 |
Macro command editing |
Fixed the defect: When the [Support Dialog] is displayed while the [Device Setting] window is displayed on the macro editing window and the data size is changed to “BIT” and overwritten, the [Device Setting] window stays displayed. |
● |
● |
● |
● |
25A0H04 |
Windows fonts |
Fixed the defect: When the [Use Windows fonts] checkbox is selected for a string, the displayed font name is not the font that is specified from [Text Font]. |
● |
● |
● |
● |
25A0H05 |
Macro command editing |
Fixed the defect: Displaying the macro editing window after an error check may result in an error. |
|
|
|
|
25A0H06 |
Macro command editing |
Fixed the defect: When the FATEK AUTOMATION FACON FBs Series (Ethernet) is selected as a PLC model, the PLC device memory port number that is set to other than “0” is changed to “0” when the macro editing window is closed and opened again. |
● |
● |
● |
● |
25A0H07 |
SX variable name cooperation |
Fixed the defect: When a V8 screen program with SX variable name cooperation is converted to a V10 screen program without cooperation and the screen program is saved and opened again, the device memory of alarm blocks becomes invalid. |
|
● |
● |
● |
25A0H08 |
Improvement of vulnerability |
Improved vulnerabilities of V7 files - Vulnerability of remote code execution caused by heap-based buffer overflow - Vulnerability of remote code execution caused by stack-based buffer overflow |
|
|
|
|
◆V10 series: System Program |
No |
Item |
Description |
Altered Ver. |
OS Ver. |
25A0T01 |
RGB adjustment |
Fixed the defect: When using RGB input on a G type V10 series unit, the [I/O Check] -> RGB Adjustment screen in Local mode does not function correctly. |
1.500 |
|
25A0T02 |
IP address setting |
Fixed the defect: Communication with a PLC cannot be established and a timeout communication error occurs under the following conditions. - A screen program that has settings at [Local Port IP Address] -> [Set IP] that differ from the V10 series unit is transferred. - IP settings are changed on the LAN Setting screen in Local mode. |
1.500 |
|
25A0T03 |
Data sheet printing |
Fixed the defect: When printing data sheets, the print position of text and data displays may be displaced considerably. |
1.500 |
|
25A0T04 |
Overlap display |
Fixed the defect: If an overlap display is continuously shown or hidden at short intervals, the actual display status of the overlap display and the registration/display status of the system device memory may become inconsistent. |
1.500 |
|
25A0T05 |
Mouse cursor |
Fixed the defect: The mouse cursor may be displayed when a certain USB keyboard that supports “AC Pan”, which is equivalent to a horizontal scroll function, is connected. |
|
1.60 |
25A0T06 |
Macro commands |
Fixed the defect: When the SYS (SAMPLE) macro command is executed, a memory leak occurs. |
1.500 |
|
25A0T07 |
Lamps |
Fixed the defect: When a screen program has the [Bring lamp items to top if the status changes] setting enabled and lamps (rendering mode: REP) are placed overlapping each other, the ON display of a lamp in the background cannot be seen because it is hidden behind the front lamp. |
1.500 |
|
25A0T08 |
Video, USB camera |
Fixed the defect: When an overlap display with a video or USB camera item is switched over continuously in a short period of time, the V10 series unit may reboot. |
1.500 |
|
◆V10 series: Communication Driver |
No |
Item |
Description |
Altered Ver. |
25A0U01 |
MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) |
Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs. - U003\G01002 - U004\G01002 |
1.710 |
25A0U02 |
MITSUBISHI ELECTRIC: FX5U/5UC series MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet) |
Fixed the defect: When communication exceeding the maximum I/O points of the PLC’s specification is attempted for multiple batch block write commands, a communication error occurs. |
1.610 1.710 |
◆V9 series: System Program |
No |
Item |
Description |
Altered Ver. |
OS Ver. |
25A0J01 |
Data sheet printing |
Fixed the defect: When printing data sheets, the print position of text and data displays may be displaced considerably. |
3.300 |
|
25A0J02 |
Overlap display |
Fixed the defect: If an overlap display is continuously shown or hidden at short intervals, the actual display status of the overlap display and the registration/display status of the system device memory may become inconsistent. |
3.300 |
|
25A0J03 |
Macro commands |
Fixed the defect: When the SYS (SAMPLE) macro command is executed, a memory leak occurs. |
3.300 |
|
25A0J04 |
Lamps |
Fixed the defect: When a screen program has the [Bring lamp items to top if the status changes] setting enabled and lamps (rendering mode: REP) are placed overlapping each other, the ON display of a lamp in the background cannot be seen because it is hidden behind the front lamp. |
3.300 |
|
◆V9 series: Communication Driver |
No |
Item |
Description |
Altered Ver. |
25A0K01 |
MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) |
Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs. - U003\G01002 - U004\G01002 |
1.710 |
25A0K02 |
MITSUBISHI ELECTRIC: FX5U/5UC series MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet) |
Fixed the defect: When communication exceeding the maximum I/O points of the PLC’s specification is attempted for multiple batch block write commands, a communication error occurs. |
1.610 1.710 |
◆TS/V8 series: System Program |
No |
Item |
Description |
Altered Ver. |
25A0G01 |
MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) |
Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs. - U003\G01002 - U004\G01002 |
1.300 |
25A0G02 |
MITSUBISHI ELECTRIC: FX5U/5UC series MITSUBISHI ELECTRIC: FX5U/5UC series (Ethernet) |
Fixed the defect: When communication exceeding the maximum I/O points of the PLC’s specification is attempted for multiple batch block write commands, a communication error occurs. |
1.200 1.300 |
|