Smart Editor Ver.1.0.3.0 → Ver.1.1.0.0 Date of Release 2025/7/18

◆Configuration Software
No Item Description TS/V8 V9 V10 X1
2570Z01 Switch, lamp An option for copying only the text can now be selected in the character properties.
2570Z02 Undo, redo Fixed the defect: Operations by an undo (Ctrl+Z) or redo (Ctrl+Y) command are is slow.
2570Z03 Data sheets Fixed the defect: When the device memory of a data display part on a data sheet is changed in the [Properties] pane of the part, the change may not be reflected.
2570Z04 Trend sampling Fixed the defect: When the [Style] tab on the [Properties] pane of a trend sampling part is displayed before transferring a screen program for which [Edit Model] is set to TS2060 or TS1000, error 46 occurs on MONITOUCH and RUN mode cannot be started, or the emulator cannot start.
2570Z05 Switch Fixed the defect: When a screen program created using V-SFT version 6 is opened using Smart Editor and the operand device memory of a word operation for a switch is selected, the device type changes from [Constant] to [Internal], and selection of [Constant] is not possible.
2570Z06 Logging server Fixed the defect: Collective setting on the logging server may forcibly terminate the editor.
2570Z07 Emulator Fixed the defect: When displaying the menu in Traditional Chinese, the text displayed upon hovering the mouse cursor over the [Emulator] icon is in Japanese ([エミュレータ]) instead of Traditional Chinese.
2570Z08 Installation Fixed the defect: When Smart Editor version 1.0.1.0 is installed from a DVD and then updated using version 1.0.3.0 which is downloaded from the website, an attempt to install the manual EXE file for version 1.0.2.0 results in an error and manual update is not possible.
2570Z09 Alarm setting Fixed the defect: When a screen program with PLC device memory specified for the [Maximum] and [Minimum] settings of [Alarm Setting] in the [Properties] pane of a numerical data display is saved, closed, and then opened again, invalid values are specified for the [Maximum] and [Minimum] settings.
2570Z10 Overlap display Fixed the defect: Smart Editor may be forcefully terminated when [Overlap Settings] -> [Display Position] -> [Specify with Mouse] is cancelled by right-clicking.
2570Z11 Overlap display Fixed the defect: When a normal overlap is placed on the normal overlap library and [Dot] or [Paint] drawing items are placed, Smart Editor may be forcefully terminated upon closing the [Overlap Settings] window by clicking [Cancel] after changing the position of the overlap from [Specify with Mouse].
2570Z12 Screen display Fixed the defect: When a screen is repeatedly closed and opened while displaying the properties of drawing parts, Smart Editor may be forcefully terminated.
2570Z13 Graphic relay Fixed the following defects regarding graphic relays:
(1) The ID of grouped graphic relays changes inadvertently.
(2) The GNo. and No. specified in the graphic library list are not reflected to the properties.
(3) The location of the icon of grouped graphic relays changes inadvertently.
2570Z14 Macro editing sheet Fixed the defect: When using a computer in a language environment other than English or Japanese and the macro editing sheet is opened and closed, an error may occur when attempting to open the sheet again, and the sheet cannot be opened.
2570Z15 Switch Fixed the defect: When a switch with [Output Action: Word Operation] and [Operation Mode: Add/Subtract/Multiply/Divide] is set, the actual operation type is opposite of what is specified.
2570Z16 Edit model change Fixed the defect: When changing the [Edit Model Selection] and the screen program is converted by enlarging to fit the resolution, the drawing toolbar and [Project] view pane may become inoperable.
2570Z17 Shortcut keys Fixed the defect: The same shortcut key is specified for [Transfer] and [Tool] on the menu bar.
2570Z18 PLC model change Fixed the defect: When changing the PLC model in [Hardware Settings] and converting device memory, the device memory type and top address can be set as desired in the device memory conversion settings, but the device memory type and address in the device memory map end up being used as the defaults for conversion.
2570Z19 Multi-language Fixed the defect: When a multi-language screen program is exported in Unicode text format and then imported as is without editing, an error message indicating that the first language does not match is displayed.