This error may be displayed on the configuration software V-SFT when data is transferred.
Possible causes and solutions are given below.
[When the transfer cable "USB" is used]
<Causes>
The USB ladder transfer function is being used but the following action is not taken (TS/V8 series only).
- The Main Menu screen is not displayed.
- "Ladder Transfer Setting" is not offline.
<Solutions>
- Display the Main Menu screen.
(Ladder communication is enabled on the RUN screen only.) - Open "Ladder Transfer Setting" and press [OFFLINE].
The screen changes as follows when [OFFLINE] is pressed.
[When the transfer cable "Ethernet" is used]
<Causes>
- The LAN cable is not connected.
- "Disconnect" is displayed at the bottom left of the Main Menu → Ethernet screen.
- The IP address set on the [Transfer]→[Communication Setting] dialog is not consistent with the IP address of the TSi/V series.
- The PC and the TSi/V series are not on the same network.
<Solutions>
- Check if the LAN cable is connected to the LAN connector correctly.
- "Disconnect" displayed at the bottom left of the Main Menu → Ethernet screen must be changed to "Connect".
- Depending on whether the hub is used or not, the cable type to use varies.
Check the cable in use.
- With hub: Straight cable
- Without hub: Cross cable - When a hub is used, check the LED that indicates the hub link condition.
If not lit, check the cable, and insert it into another empty port on the hub. - Turn on the hub again.
- Check for errors in setting, such as exchanged data between the subnet mask and default gateway of the TSi/V series.
- Depending on whether the hub is used or not, the cable type to use varies.
- Check the IP address of the TSi/V series on the Main Menu → Ethernet screen, and set it on the [Transfer]→[Communication Setting] dialog.
- Check a ping from the PC to the TSi/V series.
If not pinged, check the IP addresses of the PC and the TSi/V series.
Example: When checking or changing the IP address of the PC
[When the transfer cable "V-CP" is used]
<Causes>
- The transfer cable "V-CP" is not connected correctly.
- The COM port number set on the [Transfer]→[Communication Setting] dialog is not consistent with the COM port number of the PC.
- MJ1 is being used for another function; however, the Main Menu screen is not displayed.
- "Editor : MJ1" is not displayed at the bottom left of the Main Menu screen.
- "Modem Connect Mode" is displayed at the bottom left of the Main Menu screen.
<Solutions>
- Check if the transfer cable "V-CP" is connected correctly to the MJ1 port of the TS2060/V series.
* MJ2 port cannot be used for transfer. - Check the COM port number using the Device Manager of the PC, and set this port number for [Communication Port] on the [Transfer] →[Communication Setting] dialog.
[COM port on the PC]
Example: When USB-serial converter is used:
[Communication Setting] dialog
- When MJ1 is being used for another function as well, be sure to display the Main Menu screen before data transfer.
- When the serial ladder transfer function is being used, the indication at the bottom left of the Main Menu screen changes to "Editor : ---".
Hold down the function switch [F2] until "Editor : MJ1" is displayed, then transfer data again.
Example: V8 series
Screen transfer not possible (ladder transfer possible)
Screen transfer possible
To keep "Editor : MJ1" at the bottom left of the Main Menu screen at all times, set the screen data as shown below. TS/V8 series
Click [System Setting] → [Hardware Setting] → [Ladder Transfer] .
Check [Detail Setting] → [Ladder Communication is not Used in Local Mode] on the [Ladder Transfer Setting] dialog.
V7 series
Select [System Setting] → [Extended Communication] → [Ladder Tool] and check [Ladder Communication is not Used in Local Mode].
- When "Modem Connect Mode" is displayed, press the function switch [F5] and "Editor : MJ1" at the same time to switch to the Extended Function Setting screen.
Select "Not used" for [Modem Comm. Baud Rate] and press [Setting Finished] to move back to the Main Menu screen.
When "Modem Connect Mode" is not displayed, transfer data again.
For more information on the procedure, click here.