date: 2022/8/10

I cannot do the following in the TELLUS-HMI mode:
WAV file replay
JPEG file display
Reading and writing a recipe file [RECxxxx.csv]

 

[Causes]

  1. WAV files or JPEG files are not stored in the correct folder.
  2. For WAV file replay, settings on a screen program is not correct.

    

[Solutions]

  1. The location is set under [Generate folder at:] in the [Option] dialog box.



    [Default Position] is checked:
    In the location where the screen data in the HMI mode is stored, a folder under the name of the screen data is created.

    • For TELLUS4
      Create a WAV, a JPEG, and a RECIPE folder manually under storage>sd or usb>EXT0000 (access folder) and store these files respectively.

    • For TELLUS3
      Create a WAV, a JPEG, and a RECIPE folder manually in it and save these files respectively.

     

    [Default Position] is not checked:

    Directory to generate a folder is determined in [Option] > [Change folder].

    1. For TELLUS4
      Create a WAV, a JPEG, and a RECIPE folder manually under storage>sd or usb>EXT0000 (access folder) and store these files respectively.

For TELLUS3
Create a WAV, a JPEG, and a RECIPE folder manually in it and save these files respectively.

e.g.) TELLUS3

 

Folder File name Content
JPEG  xxxx.jpg, JPxxxxx.jpg  JPEG file
RECIPE  RECxxxx.csv, xxxxxxxx.csv  Recipe file
WAV  WAxxxx.wav  WAVE file


2. For WAV file replay, start V-SFT and go to [System Setting] > [Other] > [Storage Setting] and check [Store WAV File in storage] check box.

Was this page helpful?

Please cooperate with the questionnaire to make it better.

  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • » Inquiries about products
  • » Inquiries about sales
  • » Request for catalogs
  • » Compliance with the RoHS

MONITOUCH

LINE UP
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
Support »
  • Download
  • Inquiries
  • Recommended peripheral equipment
FAQ »
  • FAQ concerning MONITOUCH
Distributors »
  • Overseas distributors
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved