Oct. 2024 Ver. 6.2.4.0a |
---|
V10 series SYS PROG:version V1.300, OS:version V1.40 V9 series SYS PROG:version V3.100, OS:version V4.90 TS2000 series SYS PROG:version V2.440 TS1000Smart series SYS PROG:version V2.440 TS1000 series SYS PROG:version V2.440 V8 series SYS PROG:version V2.390 |
V-SFT-6: Failure fixed. |
Oct. 2024 Ver. 6.2.4.0 |
---|
V10 series SYS PROG:version V1.300, OS:version V1.40 V9 series SYS PROG:version V3.100, OS:version V4.90 TS2000 series SYS PROG:version V2.440 TS1000Smart series SYS PROG:version V2.440 TS1000 series SYS PROG:version V2.440 V8 series SYS PROG:version V2.390 |
V10 series: Newly supported devices - EPSON Printer type added. |
V-SFT-6: PLC Tabel Import/Export function added. V-SFT-6: Tag-related specification improvements Deleting unused tags V-SFT-6: Tag-related specification improvements Siemens: Importing tags V-SFT-6: Improvement of the warning message when opening a screen data of X1, V10 and V9 Other: Partial representation change of the Local mode screen |
Apr. 2024 Ver. 6.2.3.0 |
---|
V10 series SYS PROG:version V1.200, OS:version V1.30 V9 series SYS PROG:version V3.000, OS:version V4.90 TS2000 series SYS PROG:version V2.440 TS1000Smart series SYS PROG:version V2.440 TS1000 series SYS PROG:version V2.440 V8 series SYS PROG:version V2.390 |
X1/V10/V9/TS series: Newly supported devices - Fuji Electric PUM (MODBUS TCP/IP) supported. |
V10/V9/V8/TS series: Extended specifications - Selection of RS422/485 2-wire/4-wire added to KEYENCE KV Nano |
V10 series: Newly supported devices - CODESYS: CODESYS V3 (Ethernet) supported. |
V9 series: Specifications of RGB output when backlight is off extended. |
V-SFT-6: Tag import from Siemens TIA Portal V18 supported. V-SFT-6: AZERTY keyboard supported. |
Oct. 2023 Ver. 6.2.2.0 |
---|
V10 series SYS PROG:version V1.100, OS:version V1.10 V9 series SYS PROG:version V2.900, OS:version V4.80 TS2000 series SYS PROG:version V2.430 TS1000Smart series SYS PROG:version V2.430 TS1000 series SYS PROG:version V2.430 V8 series SYS PROG:version V2.390 |
X1/V10/V9/TS series: Newly supported devices - MITSUBISHI ELECTRIC FR-E800 supported. - SHINKO TECHNOS QTC1 Series(MODBUS RTU) supported. - SHINKO TECHNOS QTC1 Series(QMC1)(MODBUS RTU) supported. |
X1/V10/V9/TS series: Extended specifications - Signed BCD supported with Fuji Electric MICREX-SX F mode (MICREX-F compatible) |
V10 series: Restrictions removed (except video/RGB) |
X1/V10/V9/TS series: Centering of numerical/character display supported. V-SFT-6: Screen transfer performance improved. V-SFT-6: Batch tag device change function extended. V-SFT-6: Alarm server import/export editing function extended. V-SFT-6: Password display when entering password and re-entry of new password supported. V-SFT-6: Replacement of Sharp ZM series with MONITOUCH supported. V-SFT-6: Manufacturer name and model name of connected devices updated. V-SFT-6: Warning display during screen transfer improved. |
Jun. 2023 Ver. 6.2.1.0 |
---|
V10 series SYS PROG:version V1.000, OS:version V1.00 V9 series SYS PROG:version V2.800, OS:version V4.80 TS2000 series SYS PROG:version V2.420 TS1000Smart series SYS PROG:version V2.420 TS1000 series SYS PROG:version V2.420 V8 series SYS PROG:version V2.390 |
V-SFT-6: Failure fixed. |
Apr. 2023 Ver. 6.2.0.0 |
---|
V10 series SYS PROG:version V1.000, OS:version V1.00 V9 series SYS PROG:version V2.800, OS:version V4.80 TS2000 series SYS PROG:version V2.420 TS1000Smart series SYS PROG:version V2.420 TS1000 series SYS PROG:version V2.420 V8 series SYS PROG:version V2.390 |
X1/V10/V9/TS series: Newly supported devices - XINJE XD series(MODBUS RTU) supported. |
V10/V9/TS series: E-mail sending function expanded. V10/V9 series: USB camera function expanded. V10/V9 series: Video Player function expanded. X1 series: System memory for remaining space in built-in storage supported. X1 series: Indicator display at startup supported. V-SFT-6: V10 series supported. V-SFT-6: Tag related specifications improved. V-SFT-6: File Comparing: Source file editing function supported. V-SFT-6: Message Editing: Copy and paste in Multi-languages supported. |
Dec. 2022 Ver. 6.1.8.0 |
---|
V9 series SYS PROG:version V2.700, OS:version V4.70 TS2000 series SYS PROG:version V2.390 TS1000Smart series SYS PROG:version V2.390 TS1000 series SYS PROG:version V2.390 V8 series SYS PROG:version V2.390 |
X1/V9/TS/V8 series: Newly supported devices - MITSUBISHI ELECTRIC QnH(Q)series (Ethernet TCP/IP) supported. - Automationdirect Direct LOGIC supported. - Fuji Electric FRENIC-MEGA(G2)(MODBUS RTU) supported. |
X1/V9 series: Newly supported devices - Siemens S7-1200/1500 Optimized Tag(Ethernet ISOTCP) supported. |
V9080iSD-U20x/V9100iS-U20x supported. |
Oct. 2022 Ver. 6.1.7.0 |
---|
V9 series SYS PROG:version V2.600, OS:version V4.60 TS2000 series SYS PROG:version V2.390 TS1000Smart series SYS PROG:version V2.390 TS1000 series SYS PROG:version V2.390 V8 series SYS PROG:version V2.390 |
TS2060(i)-U20x supported. |
Apr. 2022 Ver. 6.1.6.0a |
---|
V9 series SYS PROG:version V2.600, OS:version V4.40 TS2000 series SYS PROG:version V2.390 TS1000Smart series SYS PROG:version V2.390 TS1000 series SYS PROG:version V2.390 V8 series SYS PROG:version V2.390 |
V-SFT-6: Failure fixed. |
Apr. 2022 Ver. 6.1.6.0 |
---|
V9 series SYS PROG:version V2.600, OS:version V4.40 TS2000 series SYS PROG:version V2.390 TS1000Smart series SYS PROG:version V2.390 TS1000 series SYS PROG:version V2.390 V8 series SYS PROG:version V2.390 |
X1/V9/TS/V8 series: Newly supported devices - MITSUBISHI ELECTRIC FX5U/5UC series supported. - MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) supported. - JTEKT TOYOPUC-Nano(Ethernet) supported. - Azbil NX(CPL)(Ethernet TCP/IP) supported. - SHINKO TECHNOS PCB1 series supported. - SHINKO TECHNOS JIR-301-M series supported. - SHINKO TECHNOS BCx2 series supported. |
V9 series: Newly supported devices - Hitachi HIDIC-S10/ABS Multi-link2(Ethernet) supported. |
X1/V9 series: Display conditions for Show/Hide settings extended. X1/V9 series: No. of parameter for alarm function extended. X1/V9 series: Fixed cycle 1-3 added to PLC device transfer function. X1/V9 series: IF (MULTI) macro extended. X1 series: 2-split screen supported. X1 series: Application launch function extended. (display position/size specification supported) X1 series: Task List / On-Screen Keyboard Display extended. X1 series: Reading/writing to USB memory supported. X1 series: Write filter function expanded. X1 series: Reboot button added to System Configurator. X1 series: Sound setting button added to System Configurator. X1 series: Display connection status at I/O check on the local screen supported. X1 series: Multi-display setting information in System Information on the local screen supported. V9 series: PDF viewer functionality added. V-SFT-6: Applicable Windows OS changed. (Windows 11 supported, Windows XP not supported) V-SFT-6: Tag import from Siemens TIA Portal V17 supported. V-SFT-6: Device designation of E-SX bus for MICREX-SX SPH3000MM/SPH5000M IEC mode supported. V-SFT-6: Setting to display the screen data name first in the V-SFT title bar added. V-SFT-6: Batch tag name change function added. V-SFT-6: Function to jump to the point of discrepancy when comparing files supported. V-SFT-6: Right-click menu added for Project view. V-SFT-6: Specification of password operation for sending/receiving screen data changed. |
Nov. 2021 Ver. 6.1.5.0 |
---|
V9 series SYS PROG:version V2.500, OS:version V4.30 TS2000 series SYS PROG:version V2.390 TS1000Smart series SYS PROG:version V2.390 TS1000 series SYS PROG:version V2.390 V8 series SYS PROG:version V2.390 |
V-SFT-6: Failure fixed. |
Oct. 2021 Ver. 6.1.4.0 |
---|
V9 series SYS PROG:version V2.500, OS:version V4.30 TS2000 series SYS PROG:version V2.380 TS1000Smart series SYS PROG:version V2.380 TS1000 series SYS PROG:version V2.380 V8 series SYS PROG:version V2.380 |
V9 series: Products without serial communication CPU for Siemens MPI/PPI supported. |
Oct. 2021 Ver. 6.1.3.0 |
---|
V9 series SYS PROG:version V2.400, OS:version V4.20 TS2000 series SYS PROG:version V2.380 TS1000Smart series SYS PROG:version V2.380 TS1000 series SYS PROG:version V2.380 V8 series SYS PROG:version V2.380 |
X1/V9/TS/V8 series: Newly supported devices - MITSUBISHI ELECTRIC QnU series (Built-in Ethernet ASCII) supported. - MITSUBISHI ELECTRIC FX3U/3GE series (Ethernet) connectable unit added. - JTEKT TOYOPUC (Ethernet PC10Mode) TCP/IP supported. - Allen-Bradley Tag specifications extended. - RFID controller (Stepless protocol) supported. |
X1/V9 series: Newly supported devices - MITSUBISHI ELECTRIC Q170 series (Multi CPU) (Ethernet) supported. |
V9/V8/TS series: Newly supported devices - PROFIBUS communication: Specifications of the settings of the Input/Output byte counts changed. |
X1/V9 series: Improved PDF output quality of Extended Data sheet. X1/V9 series: Always-on display function of the trend graph supported. X1/V9 series: Item select function for numerical display and character string display supported. X1/V9 series: Backup files supported for sampling macros. X1/V9 series: Specification of Scheduler function operation extended. X1/V9 series: Overlap control switch function extended. X1/V9 series: Maximum number of patterns and 3D parts bitmap areas increased. X1 series: Multi-display function supported. X1 series: Portrait mode (Right 90 degrees) supported. X1 series: Application startup method added. V9 series: USB camera portrait mode supported. V9 series: Function to rotate and save snapshots of network cameras supported. V9 series: Prohibiting screen upload supported. V9 series: OKI COREFIDO printer (B432dnw) supported. V9 series: Data transfer service function extended. TS/V8 series: Built-in clock supported for Year 2038 and later. V8 series: DMC touch switch emulation supported. V-SFT-6: Alarm server CSV import/export function extended. V-SFT-6: The maximum number of device increment steps for Multi copy increased. V-SFT-6: Function to save the file name in the screen data added. V-SFT-6: PLC connection port "LAN2" supported with edit model: TELLUS Ver.4. |
May 2021 Ver. 6.1.2.0 |
---|
V9 series SYS PROG:version V2.300, OS:version V4.10 TS2000 series SYS PROG:version V2.360 TS1000Smart series SYS PROG:version V2.360 TS1000 series SYS PROG:version V2.360 V8 series SYS PROG:version V2.360 |
V-SFT-6: Failure fixed. |
Apr. 2021 Ver. 6.1.1.0 |
---|
V9 series SYS PROG:version V2.300, OS:version V4.10 TS2000 series SYS PROG:version V2.360 TS1000Smart series SYS PROG:version V2.360 TS1000 series SYS PROG:version V2.360 V8 series SYS PROG:version V2.360 |
X1/V9/TS/V8 series: Newly supported devices - Hitachi HIDIC-S10/ABS supported. - SHINKO TECHNOS PCA1 series supported. |
TS/V8 series: Newly supported devices - BECKHOFF ADS Protocol (Ethernet) KeepAlive supported. - BECKHOFF Tag ADS Protocol (Ethernet) KeepAlive supported. |
X1/V9/V8/TS series: Display format "HEX" supported. X1/V9/V8/TS series: String type supported in S7-1200/1500 (Ethernet ISOTCP). X1/V9/TS series: N state lamp function supported. X1/V9 series: Picture viewer function supported. X1/V9 series: Trend (history) function expanded. X1/V9 series: Multi-language: up to 32 languages supported. X1/V9 series: Tabular data display: Background color transparent supported. X1/V9 series: Notepad function expanded. X1/V9 series: Additional parts supported in Data sheet printing (expanded). |
X1/V9 series: Input mode: Specification improved. - Cursor movement setting with ENT key - Copy and paste function |
X1/V9 series: Alarm / Operation / Scaling supported. - Symbol - Operation / Scaling (PLC, internal device) supported in Logging server. |
X1/V9 series: Recipe: Display of list dialog improved. X1/V9 series: Backup folder deletion function supported. X1/V9 series: Macro command comparison: IF(MULTI), SELECT_CASE supported. X1/V9 series: E-mail sending function: Encryption "STARTTLS" supported. X1/V9 series: MES Standalone supported. X1/V9 series: MITSUBISHI ELECTRIC Q170 supported for ladder monitor upload function. X1/V9 series: YOKOGAWA PLC (Ethernet connection) supported for ladder monitor. X1/V9 series: Processing cycle: Fixed cycle function supported. X1/V9 series: Initial screen number designation by "read / write area" (V8 compatible) supported. V9 series: Video Player: Storage switching function supported. V9 series: USB camera: Snap function supported. V9 series: Touch switch emulation (RGB input) Windows10 supported. *1 V9 series: Zoom-in/out function supported in PDF viewer. *2 V9 series: AXIS network camera: Free size specification of display area supported. |
V9 series: Web Machine Interface specification improvement. - Domain connection by DNS - Monitoring function settings expanded |
V9 series: System memories added for PictBridge printer. |
V9 series: New items for Display Environment added. - Connect the remote desktop function with RGB 32-bit color - Animation behavior (V8 compatible) |
V8/TS series: Additional models of Panasonic network camera supported. - BB-SW172A |
V-SFT-6: Table format supported in List of Memory Use. V-SFT-6: Unicode supported for image file names. V-SFT-6: Tabular data display: Direct modification of cell width and height supported. V-SFT-6: Warning display when opening existing screen data of X1 and V9 supported. V-SFT-6: Additional function to hide overlap windows supported. *1 V9 unit + GUR-xx (RGB-IN) *2 Advanced (Capacitance) model only. |
Dec. 2020 Ver. 6.1.0.0 |
---|
V9 series SYS PROG:version V2.200, OS:version V4.00 TS2000 series SYS PROG:version V2.340 TS1000Smart series SYS PROG:version V2.340 TS1000 series SYS PROG:version V2.340 V8 series SYS PROG:version V2.340 |
X1 series (X115 and X112) added to Edit Model. X1 series: Vector Graphics supported. X1 series: Application Alignment supported. X1 series: OPC UA (Server and Client) supported. X1 series: MQTT (Microsoft Azure) supported. X1 series: Web Browser supported. V-SFT-6: Failure fixed. |
Oct. 2020 Ver. 6.0.39.0 |
---|
V9 series SYS PROG:version V2.200, OS:version V4.00 V8 series SYS PROG:version V2.340 TS2000 series SYS PROG:version V2.340 TS1000 series SYS PROG:version V2.340 TS1000Smart series SYS PROG:version V2.340 |
V9/TS/V8 series: Newly supported devices |
V9/TS series: Newly supported devices |
V9 series: Printer type added. *1 |
V9 series: Local screen: Changes in local screen specifications. V9 series: Local screen: Expansion I/O test screen V9 series: USB camera: Extended information output device feature. V9/TS series: Screen program transfer (write) is allowed only to the V9/TS with a specific MAC address. TS series: Main menu screen: Improved signal level display for communication parameters. V-SFT-6: BECKHOFF Tag ADS Protocol (Ethernet TCP/IP) Extended function. V-SFT-6: Password protection function is supported when sending and receiving screen program data. V-SFT-6: Trend: Extended logging word count. V-SFT-6: Password lock function when editing a screen program. V-SFT-6: Multi Language Batch Copy: Extended feature V-SFT-6: Additional parts: New panel meters with dials of 90 or 270 degrees V-SFT-6: Tag Database: Extended specifications *1 OS upgrade is required. *2 Supported by V9 hardware ver. f or later. |
July 2020 Ver. 6.0.38.0 |
---|
V9 series SYS PROG:version V2.150, OS:version V3.90 TS2000 series SYS PROG:version V2.320 TS1000Smart series SYS PROG:version V2.320 TS1000 series SYS PROG:version V2.320 V8 series SYS PROG:version V2.320 |
V9/TS/V8 series: Newly supported devices |
V9/TS/V8 series: KEYENCE UG device memory (buffer memory of expansion unit) supported. |
V9 series: Printing data sheets: Line-spacing setting supported. V-SFT-6: KEYENCE XYM display of PLC device memory supported. |
Apr. 2020 Ver. 6.0.37.0 |
---|
V9 series SYS PROG:version V2.100, OS:version V3.90 V8 series SYS PROG:version V2.320 TS2000 series SYS PROG:version V2.320 TS1000 series SYS PROG:version V2.320 TS1000Smart series SYS PROG:version V2.320 |
V-SFT-6: Failure fixed. |
Apr. 2020 Ver. 6.0.36.0 |
---|
V9 series SYS PROG:version V2.100, OS:version V3.90 V8 series SYS PROG:version V2.320 TS2000 series SYS PROG:version V2.320 TS1000 series SYS PROG:version V2.320 TS1000Smart series SYS PROG:version V2.320 |
V9 series: Newly supported devices |
V9/TS/V8 series: Newly supported devices |
V9 series: VNC server: function extended. * V9 series: Operation log: function extended. * V9 series: Data sheet printing - PDF output: function extended. * V9 series: USB camera: Macro commands to stop/start event record function supported. V9 series: RESTART macro command: additional features V9 series: Additional system devices: various version information V9 series: PLC ladder monitor OMRON C series supported.(C200H/C200HX only) V-SFT-6: Tag import: Siemens TIA Portal Ver.15.1/16 supported V-SFT-6: Additional parts library V-SFT-6: Parts: Flipping image supported. V-SFT-6: Font setting: comment feature supported. V-SFT-6: Additional auto-resizing feature V-SFT-6: Table data display: additional feature V-SFT-6: Additional confirmation window V-SFT-6: Project view: additional feature V-SFT-6: Screen list: additional feature DVD: The upgrade version of V-SFT-5 is bundled to the V-SFT-6 DVD. *OS upgrading required. |
Nov 2019 Ver. 6.0.35.0 |
---|
V9 series SYS PROG:version V2.000, OS:version V3.80 V8 series SYS PROG:version V2.280 TS2000 series SYS PROG:version V2.300 TS1000 series SYS PROG:version V2.300 TS1000Smart series SYS PROG:version V2.300 |
V-SFT-6: Failure fixed. |
October 2019 Ver. 6.0.34.0 |
---|
V9 series SYS PROG:version V2.000, OS:version V3.80 V8 series SYS PROG:version V2.280 TS2000 series SYS PROG:version V2.300 TS1000 series SYS PROG:version V2.300 TS1000Smart series SYS PROG:version V2.300 |
V9/TS/V8 series: Newly supported devices |
V9 series: USB camera supported. V9 series: Alarm Server - [Put msec information on time] option supported. V9 series: Recipe dialog box - Date and time display supported. V9 series: Additional General settings V9 series: Extended system devices for IP addresses of LAN2/WLAN added. V-SFT-6: Program conversion to V9 - New dialog box for Ethernet port conversion supported. V-SFT-6: Print and Rich Text Format output - Additional menu to output extended display area supported. V-SFT-6: Recipe - Extended BIN file edit function for Memory Card mode supported. V-SFT-6: Operability of the V-SFT-6 improved. |
May 2019 Ver. 6.0.33.0 |
---|
V9 series SYS PROG:version V1.900, OS:version V3.50 V8 series SYS PROG:version V2.280 TS2000 series SYS PROG:version V2.280 TS1000 series SYS PROG:version V2.280 TS1000Smart series SYS PROG:version V2.280 |
V-SFT-6: Failure fixed. |
May 2019 Ver. 6.0.32.0 |
---|
V9 series SYS PROG:version V1.900, OS:version V3.50 V8 series SYS PROG:version V2.280 TS2000 series SYS PROG:version V2.280 TS1000 series SYS PROG:version V2.280 TS1000Smart series SYS PROG:version V2.280 |
V9/TS/V8 series: Newly supported devices |
V9 series: E-mailing with attachment file function supported. V9 series: Splash screen: visibility control of progress bar supported. V9 series: WLAN: Connection to an access point in stealth mode supported. V9 series: Additional General settings V9/TS/V8 series: Calendar display in the new era name "Reiwa" supported. V-SFT-6: "DEL_FILE" macro command supported. V-SFT-6: Operability of the V-SFT-6 improved. |
January 2019 Ver. 6.0.31.0 |
---|
V9 series SYS PROG:version V1.800, OS:version V3.40 V8 series SYS PROG:version V2.270 TS2000 series SYS PROG:version V2.270 TS1000 series SYS PROG:version V2.270 TS1000Smart series SYS PROG:version V2.270 |
V-SFT-6: Failure fixed. |
October 2018 Ver. 6.0.30.0 |
---|
V9 series SYS PROG:version V1.800, OS:version V3.40 V8 series SYS PROG:version V2.270 TS2000 series SYS PROG:version V2.270 TS1000 series SYS PROG:version V2.270 TS1000Smart series SYS PROG:version V2.270 |
V9/TS/V8 series: Newly supported devices |
TS/V8 series: Newly supported devices |
V9 series: Trend: Scaling display supported. V9 series: Switch: Storage viewer function supported. V9 series: Recipe: Improved display supported. V9 series: $u registers increased from 32K words to 64K words. V9 series: Additional General settings - Disable the animation effect of the trend (history). - Use VNC server function without user authentication - Put a message with multiple lines in one cell in CSV created by alarm data. V9/TS/V8 series: Numerals & Character display: Values appears as asterisks on a screen. V-SFT-6: Additional tag import function for OMRON NJ and Allen-Bradley V-SFT-6: OMRON NJ: Tag export function supported. V-SFT-6: Operation log: Converting assigned device notations into item comments. V-SFT-6: Recipe list display has been improved. V-SFT-6: Operability of the V-SFT-6 improved. |
August 2018 Ver. 6.0.29.0 |
---|
V9 series SYS PROG:version V1.750, OS:version V3.30 V8 series SYS PROG:version V2.260 TS2000 series SYS PROG:version V2.260 TS1000 series SYS PROG:version V2.260 TS1000Smart series SYS PROG:version V2.260 |
V9/TS/V8 series: Extended specifications |
V-SFT-6: Edit model selection: TS1000 Smart series added V-SFT-6: Importing Tags from Siemens TIA Portal Ver. 14 / Ver. 15 supported |
June 2018 Ver. 6.0.28.0 |
---|
V9 series SYS PROG:version V1.720, OS:version V3.30 V8 series SYS PROG:version V2.260 TS2000 series SYS PROG:version V2.260 TS1000 series SYS PROG:version V2.260 |
V9/TS/V8 series: Newly supported devices |
V9 series: "Panasonic network camera" Additionally supported models - BB-SW172A, BB-ST165A, BB-SP104W V9 series: "Local screen" Changes in the RGB adjustment screen V9 series: "European bitmap fonts" ISO code supported (V8-compatible) V-SFT-6: "View menu" OFF/ON status switching buttons added V-SFT-6: Screen program batch downloading (Ethernet) V-SFT-6: Improvements in Connection Device Selection dialog box V-SFT-6: "Tag database" Search function added V-SFT-6: "Switch" Lamp device setting added to Output Device menu V-SFT-6: "Multi Copy" Additional copy option |
October 2017 Ver. 6.0.27.0 |
---|
V9 series SYS PROG:version V1.600, OS:version V3.10 V8 series SYS PROG:version V2.220 TS2000 series SYS PROG:version V2.250 TS1000 series SYS PROG:version V2.250 |
V9 series: Newly supported devices |
V9 series: Stroke font (V8 compatible) supported. V-SFT-6: Importing and exporting Quick Access Toolbar supported. |
August 2017 Ver. 6.0.26.0 |
---|
V9 series SYS PROG:version V1.550, OS:version V3.00 V8 series SYS PROG:version V2.220 TS2000 series SYS PROG:version V2.240 TS1000 series SYS PROG:version V2.240 |
V9 series: Extended security function V9 series: CSV files for adding titles to sampling file (V8 compatible) reading function V9 series: Add operation for Recipe CSV files supported V9 series: $R, Internal devices for Recipe data transfer supported V-SFT-6: Titles for Recipe data editing function |
July 2017 Ver. 6.0.25.0 |
---|
V9 series SYS PROG:version V1.470, OS:version V2.90 V8 series SYS PROG:version V2.220 TS2000 series SYS PROG:version V2.240 TS1000 series SYS PROG:version V2.240 |
TS2000 series: System program fixed. TS1000 series: System program fixed. |
June 2017 Ver. 6.0.24.0 |
---|
V9 series SYS PROG:version V1.470, OS:version V2.90 V8 series SYS PROG:version V2.220 TS2000 series SYS PROG:version V2.230 TS1000 series SYS PROG:version V2.230 |
V-SFT-6: Failure fixed. |
May 2017 Ver. 6.0.23.0 |
---|
V9 series SYS PROG:version V1.470, OS:version V2.90 V8 series SYS PROG:version V2.220 TS2000 series SYS PROG:version V2.230 TS1000 series SYS PROG:version V2.230 |
V9/TS/V8 series: Newly supported devices |
April 2017 Ver. 6.0.22.0 |
---|
V9 series SYS PROG:version V1.430, OS:version V2.90 V8 series SYS PROG:version V2.220 TS2000 series SYS PROG:version V2.220 TS1000 series SYS PROG:version V2.220 |
V9/TS/V8 series: Newly supported devices |
V9 series: Remote Desktop function supported. V9 series: Area transparent of Trend display area supported. V9 series: PDF Viewer function enhanced. V9 series: Multi-line title in the CSV Format Setting of Alarm Server/Logging Server supported. V9 series: Individual device designation in the Transfer Device Setting of the Recipe Data supported. V9 series: Display items such as V8 Compatible in General Setting added. V9 series: SANEI ELECTRIC printer supported. V9 series: Specifications of Macro command SYS(RESTART) changed. V9 series: Multi-line display in Flowing Message Settings supported. V9 series: Default settings for Use the monitoring function in VPN Setting changed. V9 series: Specifications of the Communication Setting changed. TS series: VNC server function added. V-SFT-6: Switch - Transparent switch function added. V-SFT-6: Q/I/M devices in importing Tags for Siemens TIA supported. V-SFT-6: Specifications of the string registration method in String table changed. V-SFT-6: Specifications of the Control Device in Overlap during V9 conversion changed. V-SFT-6: Specifications of the ON Grid in the Grid Setting changed. |
Dec 2016 Ver. 6.0.21.0 |
---|
V9 series SYS PROG:version V1.360, OS:version V2.80 V8 series SYS PROG:version V2.190 TS2000 series SYS PROG:version V2.200 TS1000 series SYS PROG:version V2.190 |
V9/V8 series: Newly supported devices |
V9 series: TELLUS and V-Server supported. V-SFT-6: TELLUS Ver.4 supported. |
Oct 2016 Ver. 6.0.20.0a |
---|
V9 series SYS PROG:version V1.310, OS:version V2.70 V8 series SYS PROG:version V2.190 TS2000 series SYS PROG:version V2.190 TS1000 series SYS PROG:version V2.190 |
V-SFT-6: Failure fixed. |
Oct 2016 Ver. 6.0.20.0 |
---|
V9 series SYS PROG:version V1.310, OS:version V2.70 V8 series SYS PROG:version V2.190 TS2000 series SYS PROG:version V2.190 TS1000 series SYS PROG:version V2.190 |
V9 series: System Program and OS fixed. |
Oct 2016 Ver. 6.0.19.0 |
---|
V9 series SYS PROG:version V1.300, OS:version V2.60 V8 series SYS PROG:version V2.190 TS2000 series SYS PROG:version V2.190 TS1000 series SYS PROG:version V2.190 |
V9/V8 series: Newly supported devices |
VPN additional functions (retry, connection condition $s1679) |
July 2016 Ver. 6.0.18.0 |
---|
V9 series SYS PROG:version V1.270, OS:version V2.60 V8 series SYS PROG:version V2.170 TS2000 series SYS PROG:version V2.180 TS1000 series SYS PROG:version V2.170 |
V9 series: System Program fixed. V9 series: System language display in accordance with multi-language setting supported. |
July 2016 Ver. 6.0.17.0 |
---|
V9 series SYS PROG:version V1.250, OS:version V2.60 V8 series SYS PROG:version V2.170 TS2000 series SYS PROG:version V2.170 TS1000 series SYS PROG:version V2.170 |
V9/V8 series: Newly supported devices |
V9 series: Web Machine Interface Cloud Data Service Ver. 1.0 supported.(Operation to be started in August 2016) V9 series: Web Machine Interface VPN unencryption communication setting supported. V9 series: GUR-01(RGB IN-1CH) remake supported. V9 series: Network printer supported. V9 series: Scroll function added. V-SFT-6: Associating a [*.V8] file with V-SFT-6 during installation supported. |
June 2016 Ver. 6.0.16.0 |
---|
V9 series SYS PROG:version V1.230, OS:version V2.50 TS2000 series SYS PROG:version V2.160 |
V9/V8 series: Newly supported devices |
V9 series: Gothic font (V8 compatible) supported . TS series: TS2000 series supported. V-SFT-6: Selection environment - hiding other items than target select items supported. |
April 2016 Ver. 6.0.15.0 |
---|
V9 series SYS PROG:version V1.210, OS:version V2.40 V8 series SYS PROG:version V2.150 |
V9 series: Newly supported devices |
V9 series: Video / RGB unit "GUR-00", "GUR-10", and "GUR-11" supported. V9 series: Screen program transfer - TCP/IP communication supported. V9 series: DHCP server (WLAN port) supported. V9 series: Data transfer viewer supported. V9 series: Data transfer service - device designation of folder name / file name supported. Filter function supported. V9 series: Substitute function for Memory card mode (V8 compatible) supported. V9 series: Video / RGB-IN enlarge display (V8 compatible) supported. V9 series: Logging server and Alarm server - compatible $s regsiteres with buffering area supported. V9 series: SRAM capacity for Operation log function extended. V-SFT-6: Symbol import for Siemens TIA Portal supported. V-SFT-6: Microsoft Windows 10 supported. V-SFT-6: HEX designation for bit device of MITSUBISHI PLC device supported. V8 series: "GU-01","GU-10", and "GU-11" revised hardware supported. |
January 2016 Ver. 6.0.14.0 |
---|
V9 series SYS PROG:version V1.180, OS:version V2.30 V8 series SYS PROG:version V2.130 |
V9/V8 series: Newly supported devices - Yaskawa Electric MP3000 Series EXPANSION MEMOBUS(Ethernet) supported. - Lenze ServoDrive9400(Ethernet TCP/IP) supported. - Siemens S7-200 PPI Ladder Transfer Function supported. |
V9 series: GD-80E/V609E compatibility supported. |
V9 series: DHCP client function supported. |
V-SFT-6: Speed up launching when opening a screen program supported. |
November 2015 Ver. 6.0.13.0 |
---|
V9 series SYS PROG:version V1.160, OS:version V2.20 V8 series SYS PROG:version V2.130 |
V9/V8 series: Newly supported devices - FUJI FRENIC-Ace (MODBUS RTU) supported. - YOKOGAWA UT32A/35A(MODBUS RTU) supported. - YOKOGAWA UT52A/55A(MODBUS RTU) supported. - YOKOGAWA UT75A(MODBUS RTU) supported. |
V9 series: Path through function supported with external devices connected via LAN port. |
V9 series: XOR drawing mode (V8 compatible) supported with numeric data display, switches, and lamps. |
October 2015 Ver. 6.0.12.0 |
---|
V9 series SYS PROG:version V1.140, OS:version V2.10 V8 series SYS PROG:version V2.130 |
V9/V8 series: Newly supported devices - MITSUBISHI FX5U/5UC series supported. - MITSUBISHI FX5U/5UC series (Ethernet) supported. - MITSUBISHI FX3U/3GE series(Ethernet)supported. - MITSUBISHI L series CPU supported. - KEYENCE KV-7000 (Ethernet TCP/IP) supported. - FUJI PXF(MODBUS RTU) supported. - Azbil SDC15 supported. - Azbil SDC25/26 supported. - Azbil SDC45/46 supported. |
V8 series: Newly supported devices - YOKOGAWA μR10000/20000 (Ethernet TCP/IP) supported. |
V9 series: Animation Viewer supported. |
V9 series: PDF Viewer function addition |
Ladder Transfer Function:Flow Control supported (When MITSUBISHI A series CPU is selected) |
V-SFT-6: Display device address with zero suppress |
July 2015 Ver. 6.0.11.0 |
---|
V9 series SYS PROG:version V1.120, OS:version V2.00 V8 series SYS PROG:version V2.090 |
V9 series: Newly supported devices - YOKOGAWA μR10000/20000(Ethernet TCP/IP) supported. V9/V8 series: Newly supported devices - FUJI FRENIC-VG1(MODBUS RTU) supported. - FUJI HFR-K1K supported. - Azbil SDC45/46 supported. - OMRON V680S(Ethernet TCP/IP) supported. |
V9 series: V9HDCOPY macro supports data save in JPEG format. |
V9 series: Data sheet printing: Saving a PDF file without time stamp supported. |
V9 series: Alarm parts (V8 compatible) supports scroll bar function. |
V9 series: Security function supports login/logout macro commands. |
May 2015 Ver. 6.0.10.0 |
---|
V9 series SYS PROG:version V1.110, OS:version V1.90 V8 series SYS PROG:version V2.090 |
V9 series: System Program and OS fixed. |
Apr 2015 Ver. 6.0.9.0 |
---|
V9 series SYS PROG:version V1.100, OS:version V1.80 V8 series SYS PROG:version V2.090 |
V9 series: Newly supported devices - Communication units supported (CC-Link/PROFIBUS/DeviceNet) . V9/V8 series: Newly supported devices - Siemens S7-1200/1500(Ethernet ISOTCP) connection supported. - RS Automation CSD5(MODBUS RTU) connection supported. - RS Automation Moscon-F50(MODBUS RTU) connection supported. - MITSUBISHI iQ-R series(Built-in Ethernet) connection supported. - MITSUBISHI iQ-R seriles link connection supported. - MITSUBISHI iQ-R series(Ethernet) connection supported. |
V9 series: Ladder monitor supported (FUJI) |
V9 series: Ethernet network table edit from the local screen supported. |
V9 series: Selectable font size supported with alarm display (V8 compatible), bit sampling (V8 compatible), and data sampling function. |
Mar 2015 Ver. 6.0.8.0 |
---|
V9 series SYS PROG:version V1.090, OS:version V1.70 V8 series SYS PROG:version V2.090 |
V9 series: Newly supported devices - Universal serial : Word count of write command increased. |
V-SFT-6: LogToCSV (CSV conversion tool for operation log data) : V9 data (*db) supported |
Feb 2015 Ver. 6.0.7.0 |
V9 series SYS PROG:version V1.080, OS:version V1.60 V8 series SYS PROG:version V2.090 |
V9 series: System Program fixed. |
V-SFT-6: Failure fixed. |
Feb 2015 Ver. 6.0.6.0 |
V9 series SYS PROG:version V1.070, OS:version V1.50 V8 series SYS PROG:version V2.080 |
V9 series: Newly supported devices |
V9 series: Video (1ch), RGB-IN (1ch), and RGB-OUT (1ch) supported. |
Jan 2015 Ver. 6.0.5.0 |
V9 series SYS PROG:version V1.060, OS:version V1.40 V8 series SYS PROG:version V2.080 |
V9/V8 series: Newly supported devices |
V9 series: Printer type added. |
V9 series:Trend: Background function supported. |
V9 series:Text table supported. |
V9 sereis:PDF viewer supported. |
V9 series:Entry: Direct function supported. |
V9 series:FTP client function supported. |
V9 series:Ladder monitor function supported. (MITSUBISHI/OMRON/YOKOGAWA) |
V-SFT-6: V9150/V9120/V907xW/V9060 added to edit model. |
V-SFT-6: V8 added to edit model. |
V-SFT-6: Comment edit function supported with Message edit. |
Oct 2014 Ver. 6.0.4.0 |
SYS PROG:version V1.050, OS:version V1.30 |
Newly supported devices |
Overlap - Specifying superimpose color supported. |
Switch - Switching to Local Mode function supported. |
Alarm Tracking (V8 compatible) - Time lag display supported. |
Animation function supported. |
Storage setting - Pattern, 3D parts, and Windows font supported. |
Line width specified by point supported. |
Operation log - Saving settings of sort, filter, search, and display settings supported. |
Recipe - semicolon (;) as CSV file separator supported. |
VNC server - System memory supported. |
VNC authentication screen - User-defined splash screen supported. |
General Settings - Hide Check Screen supported.(Check Screen = Data Loading) |
Rotate display of the Check screen supported.(Check Screen = Data Loading) |
V-SFT-6: Widows8.1 supported. |
V-SFT-6: File conversion from V7/V6/V4/GD80 to V9 supported. |
V-SFT-6: Pasting MS Office drawings on the software supported. |
V-SFT-6: DXF file conversion feature enhanced. |
V-SFT-6: GD-80E/V609E compatible setting - color batch change supported. |
Part frame fix supported with the parts other than switch/lamp. |
Macro GET_SMPL , SAMPLE supported with V9. |
CF Card Function(VCFAcs.DLL)supported. |
Sep 2014 Ver. 6.0.3.0 |
---|
SYS PROG: version V1.040, OS: version V1.20 |
Newly supported devices |
VPN function improved. |
Macro command compatible with V8 (SYS(GET_SMPL)) supported. |
Jul 2014 Ver. 6.0.2.0 |
---|
SYS PROG: version V1.030, OS: version V1.10 |
Newly supported devices |
VPN function supported. |
Overlay display of trend graph supported. |
Storing messages into a storage supported. |
OS automatic upload function supported. |
Emulator supported. |
Recipe dialog function supported. |
V-SFT-6: High speed data transfer supported. |
V-SFT-6: MICREX-SX variable names cooperation supported. |
V-SFT-6: Chinese (simplified, traditional) and Korean supported (available with other languages than Japanese). |
V-SFT-6: Fixing 3D parts frame supported. |
V-SFT-6: Plate parts supported. |
V-SFT-6: Switch - accumulation function supported. |