V8/TS2060 series Error HKFAQ000125

date: 2021/8/5

"Import file is not selected"

When Fuji Electric MICREX-SX is selected, this error is displayed if screen data uses input/output memory (X, Y), or P link/PE link/FL-net (CPU No. 8, 9) memory.

*If you are using the V-SFT-6, see here.

 

This message is displayed on the configuration software V-SFT when the file (*.ini) output from [Export Device Information] of the PLC programming tool is not imported.

V8series|Import file is not selected

When [No] is selected, "The specified project does not exist. [-7]" will be displayed.

 

List of PLC models which require import (N mode, F mode only *)

  • MICREX-SX (T-link)
  • MICREX-SX (OPCN-1)
  • MICREX-SX (SX bus)
  • MICREX-SX SPH/SPB/SPM/SPE/SPF series
  • MICREX-SX SPH/SPB/SPM/SPE/SPF CPU
  • MICREX-SX (Ethernet)
    * The current mode setting can be viewed by selecting [File] → [Project] → [Select Memory].

 

Example: MICREX-SX SPH/SPB/SPM/SPE/SPF CPU "F mode"
V8series|Import file is not selected

 

<Solution>

  1. Output a file (*.ini) by selecting [Export] → [Device Information] of the PLC programming tool.
    For more information about [Export / Device Information], refer to the relevant PLC manual.

    Example: SX-Programmer Standard Ver. 3




  2. Click [File] → [Project] → [Import] on the screen data, and import the file output in step 1. into the screen data.

V8series|Import file is not selected

Was this page helpful?

Please cooperate with the questionnaire to make it better.

Related questions(FAQ)

  • "Import file is not selected"
  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • » 제품에 관한 문의
  • » 영업 판매 문의
  • » 카탈로그 청구
  • » RoHS 지령에 대응

MONITOUCH

라인업
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
서포트 »
  • 다운로드
  • 문의
  • 추천 주변기기
FAQ »
  • FAQ concerning MONITOUCH
대리점 »
  • Overseas distributors
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved