V8/TS2060 series Questions about HKFAQ000195

date: 2021/7/16

How to make a switch work only when the switch is held down

Follow the steps below.

 

 * If you are using the V-SFT-6, see here.

 

[V8/TS series]
Display the [Switch] dialog, select [Delay] and set for [ON delay] (units: 100 msec).

 

Example: The preset output memory operation, function or macro will be executed when the switch is held down for five seconds.
V8series|How to make a switch work only when the switch is held down

 

[V7 series]

Use a macro command.

  1. Register the operation to be executed when the switch is pressed in a macro block.
    Select [Registration Item] → [Macro Block], specify a number (not in use), and configure settings.
    Example: Turn ON M1000 in PLC memory.
                   PLC [M1000] (ON)
  2. Display the [Switch] dialog and assign a memory address that is not in use for [Output Memory].
    Example: [Output Memory]: Internal memory $u10000-00, [Output Action]: Momentary
    V8series|How to make a switch work only when the switch is held down
  3. Click [Parts] → [Macro] → [Interval Timer], and place the icon on the screen.
    V8series|How to make a switch work only when the switch is held down
  4. Display the [Interval Timer] dialog and configure as below.
    • [Timeout Time] (units: 100 msec)
    • [Use Start Memory] (the same memory address set in step 2)
    • Execution macro No. (the same macro block number set in step 1)

 

Example: Execute the macro set for interval timer macro when the switch is held down for five seconds.
 

Was this page helpful?

Please cooperate with the questionnaire to make it better.

  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • » 제품에 관한 문의
  • » 영업 판매 문의
  • » 카탈로그 청구
  • » RoHS 지령에 대응

MONITOUCH

라인업
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
서포트 »
  • 다운로드
  • 문의
  • 추천 주변기기
FAQ »
  • FAQ concerning MONITOUCH
대리점 »
  • Overseas distributors
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved