V10/V9 series Error HKFAQ000003

date: 2024/11/5

Communication Error "Simulator: Timeout", "Simulator: Link down"

This error is displayed on the V series when simulator communication is not established correctly between the V series and the PC.

 

[Communication with a PLC]

The communication setting is configured not with a PLC but with the simulator.
Configure settings for communication with a PLC in Local mode on the V series, or transfer screen data that does not require a simulator.

 

<Solutions>

Setting change procedure in Local mode

  1. Switch to Local mode on the V series.
  2. Press [Simulator Setting] in the menu icons to display the simulator settings. Select [Not Use (Actual Machine)] and press the [Apply] switch.V9series|CommunicationErrorSimulator:TimeoutSimulat
  3.  Press [RUN] in the menu icons to switch to the RUN screen.

 

Configuration procedure for not using the simulator from the configuration software

  1. Click [Transfer] -> [Download] to display the [Transfer] dialog.
  2. Uncheck [Use Simulator], and click [PC->] to transfer the screen data again.
    V9series|CommunicationErrorSimulator:TimeoutSimulat

 

 

[Communication with simulator]

The simulator is not running properly or communication is not established between the PC and the V series.

 

<Solutions>

  1. Switch to Local mode and select [Simulator Setting] -> [Use] and press the [Apply] switch.V9series|CommunicationErrorSimulator:TimeoutSimulat
    * When connecting the V series with a PC via Ethernet, the IP address of the PC must be specified at [Simulator Information]. 

  2. Press [RUN] in the menu icons to switch to the RUN screen.

  3. Click [Transfer] -> [Simulator] on the configuration software to start the simulator.V9series|CommunicationErrorSimulator:TimeoutSimulat

  4. The simulator starts up. Communication with the V series will start at the same time. Addresses related to the screen data currently open on the editor will be displayed on the simulator automatically.

V9series|CommunicationErrorSimulator:TimeoutSimulat

 

When communication is not possible:

Configure settings for communication between the PC and the V series from the [File] menu. For more information, refer to "How to check the operation of screens without connecting to a PLC."

V9series|CommunicationErrorSimulator:TimeoutSimulat

Was this page helpful?

Please cooperate with the questionnaire to make it better.

Related questions(FAQ)

  • How to check the operation of screens without connecting to a PLC
  • The V series does not switch from the RUN screen to Local mode.
  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • » 제품에 관한 문의
  • » 영업 판매 문의
  • » 카탈로그 청구
  • » RoHS 지령에 대응

MONITOUCH

라인업
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
서포트 »
  • 다운로드
  • 문의
  • 추천 주변기기
FAQ »
  • FAQ concerning MONITOUCH
대리점 »
  • Overseas distributors
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved