V10/V9 series Questions about HKFAQ000082

date: 2024/9/30

How to check the operation of screens without connecting to a PLC

Use the simulator.
The simulator allows you to verify screen operations without a PLC.
The simulator runs on a PC and simulates bit device ON/OFF action and word device data input.

V9 series|How to check the operation of screens without connecting to a PLC

 

Connection between PC and MONITOUCH

  • Serial connection
  • USB connection
  • Ethernet connection

 

[Transferring screen data]

  1. Click [File] -> [Transfer] -> [Download] on the V-SFT editor to display the [Transfer] dialog.

     

  2. Check [Use Simulator] and click the [PC ->] button to transfer the data.

    Example: For USB connection
    V9 series|How to check the operation of screens without connecting to a PLC

 

[Settings on the V10/V9 series]

  1. After transferring data, switch to Local mode and display the Simulator Setting screen.

     

  2. Configure settings on the Simulator Setting screen.

    The model names of the logical ports (PLC1 - PLC8) are displayed each with a [Not Use (Actual Machine)]/[Use] selector switch for the simulator.
    Select [Use] for devices to operate using the simulator and press [Apply].
    For connection via Ethernet (when [Comm. Mode] is set to [Ethernet (UDP)]), also set the IP address of the PC.

     

    Example: For USB connection
    V9 series|How to check the operation of screens without connecting to a PLC

     

    Example: For connection via Ethernet, also set the IP address of the PC.
    V9 series|How to check the operation of screens without connecting to a PLC

 

[Starting the simulator]

  1. Click [Transfer] -> [Simulator] on the V-SFT editor.
    The simulator starts up.

    V9 series|How to check the operation of screens without connecting to a PLC

     

    The simulator starts communicating as soon as the [Simulator] window opens.
    During communication, [Communication] → [Start] is checked, and the [Communication] icon is depressed.

    V9 series|How to check the operation of screens without connecting to a PLC

     

  2. Double-click on the [Value] cell or click [Change Setting Value] on the right-click menu.
    • Double-click

       

    • Right-click menu


  3. The [Write Device] dialog is displayed.
    Enter a value and click [OK] to update the value on the [Simulator] window.
    The input value is also displayed on the V series.
    V9 series|How to check the operation of screens without connecting to a PLC


  4. It is also possible to bit-write by clicking the ON/OFF icons in the [Simulator] window.

    V9シリーズ|PLCを接続せずに本体で動作確認をしたい

    When connecting MONITOUCH to a PLC after operations are verified, configure as below.
    1. Select [Not Use (Actual Machine)] on the Simulator Setting screen in Local mode.
      or
    2. Click [File] -> [Transfer] -> [Download] on the V-SFT editor, uncheck [Use Simulator] and transfer screen data again.

 

When communication is not successful:
If the simulator's communication settings are not correct, the V series cannot communicate with a PC properly.
If not successful, click [Communication] → [End] on the simulator to abort communication. Be sure to select [File] → [Communication Setting] and check the settings.

 

<USB communication> 
Select [File] on the simulator and check [Comm. through USB].
V9 series|How to check the operation of screens without connecting to a PLC


<Ethernet communication> 

  1. Register the IP address of the PC on the Simulator Setting screen on MONITOUCH.
    V9 series|How to check the operation of screens without connecting to a PLC

  2. Select [File] on the simulator, check that [Comm. through Ethernet] is checked, and click [Communication Setting].
    V9 series|How to check the operation of screens without connecting to a PLC

  3. Set the port number.
    The default port No. is 8020.
    If changed, set the changed port number on the Simulator Setting screen on MONITOUCH.
    V9 series|How to check the operation of screens without connecting to a PLC Default: 8020

 

<Serial communication> 

  1. Select [File] on the simulator, check that [Comm. through USB] and [Comm. through Ethernet] are not checked, and click [Communication Setting].
    V9 series|How to check the operation of screens without connecting to a PLC

  2. Set the COM number for [Communication Port]. Set the same COM number as that on the PC.
    V9 series|How to check the operation of screens without connecting to a PLC

Was this page helpful?

Please cooperate with the questionnaire to make it better.

Related questions(FAQ)

  • Communication Error "Simulator: Timeout", "Simulator: Link down"
  • Back to FAQ top

FAQ by product

  • V10/V9 series

  • V8/TS2060 series

  • TELLUS and V-Server

Most searched FAQs

  • Communication error "Error code received"
  • I want to search where these buttons are used:
    - Screen Change-over buttons
    - Overlap Control buttons
  • Communication Error "Timeout"
  • "The port cannot be opened."
  • What PLC models can be connected?
To page top
  • » 제품에 관한 문의
  • » 영업 판매 문의
  • » 카탈로그 청구
  • » RoHS 지령에 대응

MONITOUCH

라인업
  • X1 SERIES
  • V10 SERIES
  • V9 SERIES
  • TECHNOSHOT
  • Web Machine Interface
  • Smart Editor
  • V-SFT
  • TELLUS and V-Server
서포트 »
  • 다운로드
  • 문의
  • 추천 주변기기
FAQ »
  • FAQ concerning MONITOUCH
대리점 »
  • Overseas distributors
  • » Privacy Policy
Copyright©2013 Hakko Electronics Co., Ltd. All Right Reserved