| V808Ichx | V808Chx | ||
|---|---|---|---|
| Power supply | Rated voltage | 24 V Dc | |
| Permissible range of voltage | 24V Dc±10% | ||
| Permissible momentary power failure | Within 1ms | ||
| Demand (maximum rating) | 10W or less | ||
| Inrush current | 20A, 2ms | ||
| Insulation resistance | 500V Dc, 10MΩ or more | ||
| Physical environment | Operation ambient temperature | 0°C ~ +40°C | |
| Storage ambient temperature | -10°C ~ +60°C | ||
| Operation ambient humidity | 85%Rh or less (without dew condensation, Max. wet bulb temperature: 39 or lower) *1 | ||
| Atmosphere | Not exposed to corrosive gas or conductive dust | ||
| Operation altitude | 2,000 meter or lower | ||
| Contamination level*2 | Level 2 | ||
| Mechanical | Resistance to oscillation | Vibration frequency: 10~150Hz, acceleration: 9月8日m/s2(1.0G) pulsating width: 0.075mm, X,Y,Z: 3 directions 1 hour each way | |
| Resistance to shock | Pulse shape: half-sine, peak acceleration: 147m/s2(15G), X,Y,Z: 3 directions, six times each way | ||
| Electric | Noise proof | 1000Vp-p (pulse width 1 s, pulse rise time : 1ns) | |
| Static discharge | Complies with Iec61000-4-2, contact: 6Kv, air: 8Kv | ||
| Installation conditions | Grounding | Grounding resistance : Less than 100Ω , Fg/SG separation | |
| Structure | Protection Structure (front panel):IP65-compliant (with interface cover, Cf card interface cover, and LAN cover) | ||
| Cooling system | Natural air cooling | ||
| Weight | Approx.1月2日kg | ||
| Dimensions W×H×D(mm) | 259.0×232.0×55.0(without the emergency stop switch) | ||
| Case color | Black | ||
| Material | PC/Abs | ||
| V808Ichx | V808Chx | |||
|---|---|---|---|---|
| Display specifications | Screen memory | 12月5日MB | 4月5日MB | |
| Display device | Tft color Lcd | |||
| Resolution W:H(dots) | 640×480 | |||
| Display size | 7月5日 inches | |||
| Colors | 65,536 colors (without blinks)/ 32,768 colors (with blinks) | |||
| Backlight | Ccfl | |||
| Backlight Auto Off | Lit in normal (Set by the user) | |||
| Power lamp | Lit in normal condition, blinks in alarm condition such as blowout of backlight bulbs | |||
| Contrast adjustment | Fixed | |||
| Brilliance control | Fixed | |||
| Number of characters | 1月4日 size | 80 columns × 60 lines | ||
| 1-byte | 80 columns × 30 lines | |||
| 2-byte | 40 columns × 30 lines | |||
| Enlargement of characters | X: 1~8 times Y: 1~8 times | |||
| Touch switch | Switch resolution | Analog: 1,024×1,024 | ||
| Mechanical life | 1 million times or more | |||
| Surface treatment | Hard coating, Non glare finish 5% | |||
| Function switch | Number of function switches | 12 switches(4 switches:External Output) | ||
| Method | Membrane switch | |||
| Mechanical Life | 1 million times or more | |||
| Emergency Stop Switch | Method | Push-lock type (contact b, dual-circuit) | ||
| Mechanical Life | 100,000 times or more | |||
| Rated Voltage | 24V Dc | |||
| Rated Current | 1A(load resistance) | |||
| Key Switch | Number of Contacts | Contact a, single-circuit | ||
| Mechanical Life | 250,000 times or more | |||
| Electrical Life | 100,000 times or more(switching frequency: 1,200 times/hour) | |||
| Deadman Switch (3-position) | Method | 3-position (contact a, dual-circuit*) | ||
| Mechanical Life | Off → On: One million times or more Off → On → Off: 100,000 times or more | |||
| Rated Voltage | 24V Dc | |||
| Rated Current | 1A(load resistance) | |||
| Deadman Switch (Momentary) | Method | Momentary | ||
| Mechanical Life | 1 million times or more | |||
| External interface | Tb2(Terminal Block) | RS-232C, Asynchronous type, Data length : 7,8 bits, Parity : even, odd, none, Stop bit : 1,2 bits, Baud rate : 4800, 9600, 19200, 38400, 57600, 76800, 115200bps | ||
| Tb3(Terminal Block) | RS-422/485, Asynchronous type, Data length : 7,8 bits, Parity : even, odd, none, Stop bit : 1,2 bits, Baud rate : 4800, 9600, 19200, 38400, 57600, 76800, 115200, 187500 *3bps | |||
| Cf card interface | Compatible with CompactflashTm | |||
| Ethernet | Complies with Ieee802月3日 Baud rate: 10Mbps, 100Mbps Cable: 100Ω Unsealed twist pair, Category 5, Max length: 100m | - | ||
| USB | Type A, Type B (Ver1月1日) | |||
| Clock & Back up memory | Battery | Coin-type lithium primary battery | ||
| Back up memory(SRAM) | 512KB | 128KB | ||
| Back up period | 5 years (Ambient temperature 25°C) | |||
| Calendar accuracy | Gap±90 sec. per month (Ambient temperature 25°C) | |||

( mm)
| Side view | Front view | Rear view |
|---|---|---|
![]() | ![]() | ![]() |
| Bottom view | Top view |
|---|---|
![]() | ![]() |
Display
Power lamp
Function switch
CF card slot (CF)
Dip switch
Power supply
100BASE-TX/10BASE-T port (LAN)
USB-B (slave)
Screw port for fixing USB cable lock
Deadman switch
Key switch
OPERATION lamp
External output switch
Emergency stop switch
Cable insertion slot
Battery
Terminal block(TB2)
Terminal block(TB3)
| Item | Description | Language | Updated date | File size | |
|---|---|---|---|---|---|
| Hardware Specifications | Hardware specifications for V808CH series 2019Ne2 | Eng | 8月10日/2012 | 13,996KB | Download |
| Connection Manual | The connection and communication parameters for the V8 series and controllers are explained in details. 2201Ne12 | Eng | 8月10日/2012 | 34,912KB | Download |
| CAD | CAD Data of V808CH series | Eng | 7月1日/2009 | 11,582KB | Download |
| i: | With built-in LAN port |
|---|---|
| None: | Without built-in LAN port |
| Key switch | Deadman switch | ||
|---|---|---|---|
| Method | External output | ||
| 0 | None | Momentary | None |
| 1 | Provided | Momentary | None |
| 2 | None | 3-position | 1 contact |
| 3 | Provided | 3-position | 1 contact |
| 4 | None | 3-position | 2 contact |